Effects of angiotensin receptor blockers on neointimal characteristics in angina patients requiring stent implantation: optical coherence tomography analysis

نویسندگان

  • Jae Young Cho
  • Soon Jun Hong
  • Do-Sun Lim
چکیده

BACKGROUND Angiotensin receptor blockers (ARBs) are known for its anti-inflammatory and anti-proliferative effects. The aim of the study was to evaluate long-term effects of ARBs on morphologic characteristics of stent restenosis in patients with coronary artery disease requiring stent implantation by optical coherence tomography (OCT). METHODS Patients with coronary artery disease having history of drug-eluting stent implantation (n = 407) were analyzed on the basis of ARB therapy as the ARB group (n = 162) and the non-ARB group (n = 245). Neointimal characterizations were performed at lesions with diameter stenosis >30% with OCT in each group. Major adverse cardiovascular events (MACEs), lumen area, stent area, neointimal area, neointimal thickness, nonapposed struts, uncovered struts, and intraluminal mass between two groups were also observed. RESULTS More patients in the ARB group revealed homogeneous and layered neointimal pattern (44.9% vs. 35.6%, P < 0.001, and 16.8% vs. 10.6%, P < 0.001, respectively), and whereas patients in the non-ARB group revealed heterogeneous neointimal pattern (1.1% vs. 7.6%, P < 0.001). Mean neointimal area (1.09 ± 1.00 mm2 vs. 1.38 ± 1.24 mm2) and mean neointimal thickness (140.6 ± 112.0 μm vs. 189.6 ± 423.1 μm) with OCT were smaller in the ARB group when compared to the non-ARB group. Percentage of covered stents was significantly higher in the ARB group when compared to the Non-ARB group (97.3% vs. 92.6%, P = 0.015). Other factors such as follow-up % diameter stenosis, late lumen loss, binary restenosis, MACEs, various neointimal characteristics analyzed by image analyzing software did not show significant differences. CONCLUSION The use of ARBs after drug-eluting stent implantation demonstrated difference in neointimal characteristics, less amount of neointimal area and fewer number of uncovered stent struts during the follow-up OCT, indicating the anti-proliferative and anti-inflammatory effects of ARBs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors for neoatherosclerosis: a retrospective observational study from the optical coherence tomography registry.

BACKGROUND Recent studies have reported development of neoatherosclerosis (NA) inside the stents several years after stent implantation. The aim of this study was to determine the predictors for NA using optical coherence tomography. METHODS AND RESULTS From a total of 1080 patients who underwent optical coherence tomography, we identified 179 stents in 151 patients in which the mean neointim...

متن کامل

Stent Evaluation with Optical Coherence Tomography

Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intr...

متن کامل

Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.

OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...

متن کامل

Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.

BACKGROUND We report findings from optical coherence tomography (OCT) of in-stent neoatherosclerosis as a cause of drug-eluting stent (DES) failure. METHODS AND RESULTS Optical coherence tomography and grayscale and virtual histology intravascular ultrasound were performed in 50 patients (30 stable, 20 unstable angina) with 50 DES in-stent restenosis lesions and intimal hyperplasia >50% of st...

متن کامل

Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation.

BACKGROUND The differences between using sirolimus-eluting stents (SESs) and paclitaxel-eluting stents (PESs) in the vascular response at 9 months after implantation were examined with optical coherence tomography (OCT). METHODS AND RESULTS OCT was carried out in 33 SESs [33 patients, 19 with acute coronary syndrome (ACS) and 14 with stable angina pectoris (SAP)] and 27 PESs (27 patients, 15 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017