Worth the effort?: closed-loop infusion pump integration with the EMR.
نویسندگان
چکیده
Disclosure: The authors are employees of CareFusion, which holds many patents, including those associated with clinical device operating parameters. They also were employed by the predecessor companies that were involved in developing modular smart intravenous (IV) infusion safety systems and the associated wireless connectivity. This article reports their firsthand experience of what it took, and their understanding of what hospitals need to know, to achieve reliable, scalable, repeatable, closed-loop IV infusion pump integration with the electronic medical record (EMR). The article is based on their combined 50-plus years of experience in IV infusion safety and on a series of recent interviews with thought leaders and senior personnel at early-adopter healthcare organizations. The leading cause of patient harm is medications, which account for almost 20% of medical injuries. Intravenous (IV) infusion errors, which involve high-risk medications delivered directly into a patient’s bloodstream, have been identified as having the greatest potential for patient harm. Many hospital administrators think that the combination of computerized provider order entry (CPOE) and barcode medication administration (BCMA) protects patients from serious adverse drug events (ADEs)— but neither CPOE nor BCMA safeguards patients against many types of IV infusion errors (Figure 1). Darren Dworkin, vice president of enterprise information systems and chief information officer of the Cedars-Sinai Health System in Los Angeles, says, “There’s no one thing that you can do to prevent errors. We have lots of data that show that having invested and implemented CPOE and BCMA significantly improves medication safety, but we also have data that show we still have room to improve to get to zero IV drug therapy errors. We need to find a way to fix that by tackling the whole problem.” IV infusions present the greatest medication safety challenges because of their high potential for harm and how they are administered. For an oral solid, intramuscular injection, or eye drops, administering a dose is a one-point-in-time event. For an IV infusion, administration is a process that continues over time and may involve many About the Authors
منابع مشابه
Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier.
New effort has been made to develop closed-loop glucose control, using subcutaneous (SC) glucose sensing and continuous subcutaneous insulin infusion (CSII) from a pump, and a control algorithm. An approach based on a model predictive control (MPC) algorithm has been utilized during closed-loop control in type 1 diabetes patients. Here we describe the preliminary clinical experience with this a...
متن کاملCombining insulin pumps and continuous glucose monitors; where are we to go from here?
Insulin pump development started in 1978, with the first commercially available glucose sensor marketed in 1999. Combining these two instruments is a logical step toward the closed loop. This article discusses three questions: Is pump development complete? How can a pump and a sensor be combined? Can the delay problem associated with the subcutaneous-subcutaneous approach for the closed loop be...
متن کاملDevelopment of individual insulin infusion profiles for open loop infusion systems.
A computer controlled syringe-type insulin infusion pump storing up to 254 different infusion rates, eight different meal programs and two different basal rates automatically changeable during 24 h in EPROM was used for insulin infusion applying a wavy step profile. This profile approaching the physiological postprandial insulin secretion of the B-cell was calculated by an algorithm following t...
متن کاملCoordination of a Bi-Level Closed-Loop Supply Chain considering Economic and Green Transportation Modes
In recent years, comprehensive researches have provided ample support for the supply chains in the coordinated decision-making framework. However, the issue of closed-loop supply chain coordination considering various transportation modes has not yet been addressed in the literature. In this paper, a two-echelon closed-loop supply chain consisting of a manufacturer and a retailer is investigate...
متن کاملAn Experimental Investigation into the Effects of High Viscosity and Foamy Oil Rheology on a Centrifugal Pump Performance
This paper presents the effect of high viscosity oil and two-phase foamy-oil flow on the performance of a single stage centrifugal pump. As a part of this, the applicability of a pipe viscometer to determine the foamy oil viscosity is investigated. Unlike previous studies, a sealed fluid tank is used in a closed flow loop to allow conditioning the two-phase mixture to create foamy-oil. Furtherm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical instrumentation & technology