Pulsatile mode of operation of left ventricular assist devices and pulmonary haemodynamics.

نویسنده

  • Michael Poullis
چکیده

OBJECTIVES To determine the effect of differing modes of left ventricular assist device (LVAD) operation: synchronous, independent (asynchronous or pseudosynchronous) or counter pulsation (antisynchronous), on left atrial pressure, pulmonary artery pressure, pulmonary blood flow and right ventricular work load, utilizing a previously published electrical analogy of the systemic and pulmonary circulation and the heart. METHODS A previously published electrical analogy of the systemic and pulmonary circulation was utilized. The Simulation Package with Integrated Circuit Emphasis (LTSPICE IV) was utilized. Three LVAD operation mode scenarios were analysed: synchronous, counter pulsation and independent pulsatile. The root mean square of the pulmonary artery pressure (PAP), left atrial pressure (LAP) and pulmonary blood flow (PBF) were calculated, as was the right ventricular work load. RESULTS Counter pulsation LVAD operation resulted in the lowest LAP, PAP, right ventricular work load and the highest pulmonary blood flow. Independent pulsation resulted in the highest LAP, PAP and the lowest pulmonary blood flow. This technique actually increased RV work load. CONCLUSIONS If an LVAD is to be operated in a pulsatile mode, the counter pulsation mode reduces pulmonary artery and left atrial pressure and increases pulmonary blood flow and thus cardiac output. This is in addition to the reduced right ventricular energetic requirement, a finding previously described. Clinical validation of our findings is necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.

OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...

متن کامل

A mathematical model to evaluate control strategies for mechanical circulatory support.

Continuous flow ventricular assist devices (VADs) for mechanical circulatory support (MCS) are generally smaller and believed to be more reliable than pulsatile VADs. However, regarding continuous flow, there are concerns about the decreased pulsatility and ventricular unloading. Moreover, pulsatile VADs offer a wider range in control strategies. For this reason, we used a computer model to eva...

متن کامل

Shear Stress, Energy Losses, and Costs: A Resolved Dilemma of Pulsatile Cardiac Assist Devices

Cardiac assist devices (CAD) cause endothelial dysfunction with considerable morbidity. Employment of pulsatile CAD remains controversial due to inadequate perfusion curves and costs. Alternatively, we are proposing a new concept of pulsatile CAD based on a fundamental revision of the entire circulatory system in correspondence with the physiopathology and law of physics. It concerns a double l...

متن کامل

Continuous flow left ventricular assist devices: a valid option for heart failure patients.

Recent outstanding clinical advances with new mechanical circulatory systems (MCS) have led to additional strategies in the treatment of end stage heart failure (HF). Heart transplantation (HTx) can be postponed and for certain patients even replaced by smaller implantable left ventricular assist devices (LVAD). Mechanical support of the failing left ventricle enables appropriate hemodynamic st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2014