Laser nephelometry and radial immunodiffusion compared for immunoglobulin quantification in pathological sera.

نویسندگان

  • H Cloppet
  • A Francina
  • H Coquelin
  • Y Boucaud-Maître
  • P Hutinel
  • R Creyssel
چکیده

We evaluated nephelometers from Behring, Hyland, and Beckman for IgG, IgA, and IgM quantitation in sera from patients with monoclonal gammopathies. The intra-batch precision of each instrument for each immunoglobulin class and for different concentrations of the same immunoglobulin was compared to the one obtained with the radial immunodiffusion method. No nephelometer showed a clearly better precision. The correlation with cellulose acetate electrophoresis was good for each of the three nephelometers. The mean value by the radial immunodiffusion method was higher than corresponding determinations by nephelometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.

Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA prote...

متن کامل

Six approaches to routine quantification of human monoclonal immunoglobulin M compared.

Six routine techniques for the determination of monoclonal IgM are compared: standard electrophoresis, the Technicon AIP system, Hyland laser nephelometry, Beckman Immunochemistry System, Behring laser nephelometry, and radial immunodiffusion. The data are evaluated by use of a nonparametric statistical analysis of variance by ranks (Friedman test) and Wilcoxon's test. The 27 sera containing mo...

متن کامل

Laser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.

Quantification of immunoglobulins IgG, IgA, IgM, C3 complement, siderophilin, alpha 2-macroglobulin and haptoglobin in serum by a Behring laser nephelometer coupled with a date processing apparatus was compared with values obtained by the radial immunodiffusion method of Mancini. The precision was not improved by the use of the laser nephelometer as compared to Mancini radial immunodiffusion, b...

متن کامل

Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radi...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 1982