Fluid-structure interaction study of the edge-to-edge repair technique on the mitral valve.
نویسندگان
چکیده
The effect of functional mitral regurgitation has been investigated in an anatomically sized, fluid-structure interaction mitral valve model, where simulated correction has been performed by applying: (1) edge-to-edge repair with annuloplasty and (2) edge-to-edge repair only. Initially defined in an open unstressed/corrected configuration, fluid-structure interaction simulations of diastole have been performed in a rigid ventricular volume. Comparison of the maximum principal stresses (during diastole) in the normal and repaired models has shown that the magnitude of stress in the repaired scenarios is ~200% greater. The combined edge-to-edge and annuloplasty procedure was found to spread the induced stresses across the free margin of the leaflets, whereas without annuloplasty a localised stress concentration in the region of the suture was observed. Fluid flow downstream of the corrected configurations was able to achieve the same magnitude as in the normal case, although the flow rate was impaired. The maximum flow rate was found to be reduced by 44-50% with the peak flow rate shifted from the end of the diastole in the normal case to the start in the repaired cases.
منابع مشابه
Endovascular Edge-to-Edge Mitral Valve Repair
Background—The edge-to-edge technique is an accepted method for the surgical repair of a regurgitant mitral valve. This study reports the initial use of an endovascular technology that enables a double-orifice edge-to-edge mitral valve repair without cardiopulmonary bypass in an animal model. Methods and Results—Adult pigs (n 14) were anesthetized, and left thoracotomy was performed for epicard...
متن کاملFinite element analysis for edge-to-edge technique to treat post-mitral valve repair systolic anterior motion.
Systolic anterior motion of the mitral valve is an uncommon complication of mitral valve repair, which requires immediate supplementary surgical action. Edge-to-edge suture is considered as an effective technique to treat post-mitral valve repair systolic anterior motion by clinical researchers. However, the fundamentals and quantitative analysis are vacant to validate the effectiveness of the ...
متن کاملThe edge-to-edge technique for mitral valve repair
The edge-to-edge technique was introduced in the surgical armamentarium of mitral valve repair in 1991 and has progressively been used to restore mitral competence in the setting of degenerative, post-endocarditis and functional mitral regurgitation. Appropriate indications and awareness of the important technical aspects of the procedure are prerequisites for a good outcome. The free edges of ...
متن کاملThe evolution from surgery to percutaneous mitral valve interventions: the role of the edge-to-edge technique.
The edge-to-edge technique is a versatile procedure for mitral valve repair. Its technical simplicity has been the prerequisite for the development of a number of transcatheter technologies to perform percutaneous mitral valve repair. The evolution from a standard open heart surgical to percutaneous procedure involved the application of the technique in minimally invasive robotic surgery and di...
متن کاملRepair of Mitral Valve Using Triangular Resection of Anterior Leaflet & Annuloplasty Ring
Various surgical techniques have been described for the repair of mitral valve with or without using an annuloplasty ring depending upon the pathological changes. Isolated prolapse of the anterior mitral leaflet with severe mitral regurgitation is relatively uncommon compared to prolapse of the posterior mitral leaflet. The technique commonly used is edge-to-edge repair, Chordal transfer and sh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 44 13 شماره
صفحات -
تاریخ انتشار 2011