Carbon dioxide insufflation is associated with increased serrated polyp detection rate when compared to room air insufflation during screening colonoscopy

نویسندگان

  • Michael Riverso
  • Yaseen B. Perbtani
  • Jonathan J. D. Shuster
  • Joydeep Chakraborty
  • Tony S. Brar
  • Mitali Agarwal
  • Han Zhang
  • Anand Gupte
  • Shailendra S. Chauhan
  • Christopher E. Forsmark
  • Peter V. Draganov
  • Dennis Yang
چکیده

BACKGROUND AND STUDY AIMS  Sessile serrated adenomas (SSA) and traditional serrated adenomas (TSA) have been increasingly recognized as precursors of colorectal cancer. The aim of this study was to compare the effect of carbon dioxide insufflation (CO 2 I) vs. room air insufflation (AI) on serrated polyp detection rate (SPDR) and to identify factors associated with SPDR. PATIENTS AND METHODS  Single-center retrospective cohort study of 2083 screening colonoscopies performed with AI (November 2011 through January 2013) or CO 2 I (February 2013 to June 2015). Data on demographics, procedure characteristics and histology results were obtained from a prospectively maintained endoscopy database and chart review. SPDR was defined as proportion of colonoscopies in which ≥ 1 SSA, TSA or hyperplastic polyp (HP) ≥ 10 mm in the right colon was detected. Multi-variate analysis (MVA) was performed to identify predictors of SPDR. RESULTS A total of 131 histologically confirmed serrated polyps (129 SSA, 2 TSA and 0 HP ≥ 10 mm) were detected. SPDR was higher with CO 2 I vs. AI (4.8 % vs. 1.4 %; P  < 0.0001). On MVA, CO 2 I was associated with higher SPDR when compared to AI (OR: 9.52; 95 % CI: 3.05 - 30.3). Both higher body mass index (OR 1.05; 95 % CI:1.02 - 1.09) and longer colonoscope withdrawal time (OR 1.11; 95 % CI: 1.07 - 1.16) were also associated with higher SPDR. CONCLUSION CO 2 I is associated with higher SPDR when compared to AI during screening colonoscopy. While the mechanism remains unknown, we speculate that the favorable gas characteristics of CO 2 compared to room air results in improved polyp detection by optimizing bowel insufflation. These findings suggest an additional reason to prefer the use of CO 2 I over AI during colonoscopy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of warm carbon dioxide insufflators does not affect intra-colonic gas temperature and has no effect on polyp detection rate during colonoscopy – a randomized controlled trial

BACKGROUND AND STUDY AIMS  Methods to improve polyp detection during colonoscopy have been investigated, with conflicting results for warm water irrigation. Carbon Dioxide (CO 2) warmed to 37 °C may have similar or more pronounced effects on bowel motility. This study aimed to assess whether warmed CO 2 would improve polyp detection compared to room temperature air insufflation. PATIENTS AND ...

متن کامل

“Cat Scratch Colon” and Cecal Barotrauma perforation during colonoscopy using CO2 insufflation

Cecal perforation due to barotrauma is an increasingly recognized complication of colonoscopy when using room air for insufflation. CO2 is increasingly being utilized for insufflation due to more rapid absorption compared to ambient air and results in reduced post-procedural pain and flatulence. Use of CO2 is thought to protect against barotrauma injury, and use of CO2 during endoscopy has not ...

متن کامل

Does carbon dioxide insufflation impact adenoma detection rate? A single-center retrospective analysis

Background and study aims: Carbon dioxide (CO2) has been associated with reduced post-procedural pain and improved patient satisfaction when compared to air insufflation (AI). The effect of CO2 insufflation (CO2I) on the adenoma detection rate (ADR) remains unclear. The aims of this study are to compare ADR in patients undergoing screening colonoscopy with AI vs. CO2I and identify predictors of...

متن کامل

NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.

BACKGROUND To eliminate the risk of combustion during electrosurgical procedures and to reduce patient discomfort, carbon dioxide (CO2) insufflation has been recommended during colonoscopy. However, air insufflation is still the standard method, perhaps due to the lack of suitable equipment and shortage of randomised studies. AIMS This randomised controlled trial was conducted to assess patie...

متن کامل

Carbon dioxide insufflation during screening unsedated colonoscopy: a randomised clinical trial

One of the methods used to reduce pain and discomfort during colonoscopy is insufflation of carbon dioxide instead of air. However, the actual benefit of carbon dioxide insufflation is not unequivocally proven. The aim of the study was to evaluate the advantages of carbon dioxide insufflation during screening colonoscopy. A total of 200 patients undergoing screening colonoscopy between 2010 and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017