Electron Energy Distribution Function Measurements by Langmuir Probe in ITER like Negative Ion Sources

نویسندگان

  • B. Crowley
  • D. Homfray
چکیده

Related Articles Measurement of ion and electron temperatures in plasma blobs by using an improved ion sensitive probe system and statistical analysis methods Rev. Sci. Instrum. 83, 023502 (2012) Diagnostics of the ITER neutral beam test facility Rev. Sci. Instrum. 83, 02B103 (2012) Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe Rev. Sci. Instrum. 83, 02A306 (2012) Electron energy distribution function and plasma parameters across magnetic filters Appl. Phys. Lett. 100, 044102 (2012) Evidence cross-validation and Bayesian inference of MAST plasma equilibria Phys. Plasmas 19, 012506 (2012)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Caesium influence on plasma parameters and source performance during conditioning of the prototype ITER neutral beam injector negative ion source

Systematic Langmuir probe measurements were performed during the caesium (Cs) conditioning of the IPP prototype negative hydrogen ion source. Conditioning consists of slowly injecting caesium into the source in order to increase the extracted negative ion current and minimize the co-extraced electrons. This process usually takes several days. Measurements were taken near the plasma grid where t...

متن کامل

Measurement of electron temperatures of Argon Plasmas in a High-Density Inductively-Coupled Remote Plasma System by Langmuir Probe and Optical-Emission Spectroscopy

We measured electron density and electron energy distribution function (EEDF) in our reactor by a Langmuir probe. The EEDF of Ar plasma in the reactor could largely be described by the Maxwell-Boltzmann distribution function, but it also contained a fraction (~10) of electrons which were much faster (20-40 eV). The peak of the fast-electron tail shifted from E ~ 35 eV at 11 μbar to E ~ 25 eV wh...

متن کامل

Short DCDischarge withWall Probe as a Gas Analytical Detector

A new approach leading to the development of gas analytical detectors is reported. The approach is based on measurements in the near-cathode plasma of fine structures associated with atomic and molecular plasma processes of the high energy portion of the electron energy distribution function (EEDF). A short (without positive column) dc discharge with cold cathode and conducting walls was used. ...

متن کامل

Thermal Electron Energy Distribution Measurements in the Ionosphere

-Results of electron spectrometer and cylindrical Langmuir probe measurements of ionospheric electron energy distribution in the range from about 0.2 eV to 4-0 eV are presented and discussed in this paper.

متن کامل

Development of H− and D− ion sources for plasma heating

Related Articles Plasma studies on electron cyclotron resonance light ion source at CEA/Saclay Rev. Sci. Instrum. 83, 02A349 (2012) Transport of intense ion beams and space charge compensation issues in low energy beam lines (invited) Rev. Sci. Instrum. 83, 02B320 (2012) Status of the ion sources developments for the Spiral2 project at GANIL Rev. Sci. Instrum. 83, 02A915 (2012) A study of H+ pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012