OBJECTIVES Clinical trials of spinal cord stimulation (SCS) have largely focused on conversion from trial to permanent SCS and the first years after implant. This study evaluates the association of type of SCS and patient characteristics with longer-term therapy-related explants. MATERIALS AND METHODS Implanting centers in three European countries conducted a retrospective chart review of SCS systems implanted from 2010 to 2013. Ethics approval or waiver was obtained, and informed consent was not required. The chart review recorded implants, follow-up visits, and date and reasons for any explants through mid-2016. Results are presented using Cox regression to determine factors associated with explant for inadequate pain relief. RESULTS Four implanting centers in three countries evaluated 955 implants, with 8720 visits over 2259 years of follow-up. Median age was 53 years; 558 (58%) were female. Explant rate was 7.9% per year. Over half (94 of 180) of explants were for inadequate pain relief, including 32/462 (6.9%) of implants with conventional nonrechargeable SCS, 37/329 (11.2%) with conventional rechargeable and 22/155 (14.2%) with high-frequency (10 kHz) rechargeable SCS. A higher explant rate was found in univariate regression for conventional rechargeable (HR 1.98, p = 0.005) and high-frequency stimulation (HR 1.79, p = 0.035) than nonrechargeable SCS. After covariate adjustment, the elevated explant rate persisted for conventional rechargeable SCS (HR 1.95, p = 0.011), but was not significant for high-frequency stimulation (HR 1.71, p = 0.069). CONCLUSIONS This international, real-world study found higher explant rates for conventional rechargeable and high-frequency SCS than nonrechargeable systems. The increased rate for conventional rechargeable stimulation persisted after covariate adjustment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P-51: Treatment of Sexual Dysfunction in Patients with Spinal Cord Injury

Background Regaining arm and hand function was deemed the most important by quadriplegics, while regaining sexual function was given the highest priority for paraplegics. Improving bladder and bowel function was of shared importance to both injury groups. The objective of this study was to conduct a systematic review and meta-analysis of the existing research on patients with spinal cord injury...

متن کامل

A Brief Review of New Advances in the Treatment of Spinal Cord Injuries

Introduction: Spinal Cord Injuries (SCIs) are the main factor in the sensory disorders, which are caused by spinal cord strikes such as car accidents. Previously it was thought that SCIs could not be treated. However, new advances in neurology showed possible treatment to relieve pain in these patients. This article presents a brief review about physiology of spinal cord, kinds of injuries and ...

متن کامل

Comparison of Agonist vs. Antagonist Stimulation on Triceps Surae Spasticity in Spinal Cord

Objectives: One of the most common and disabling complications that affects individuals with spinal cord injury is spasticity. The purpose of this study is to compare the effect of agonist and antagonist electrical stimulations on triceps surae muscle spasticity in patients with spinal cord injury. Methods: A total of 30 subjects with spinal cord injury were considered for the study. They were...

متن کامل

Case series on variable presentation of ligamentum flavum stimulation following percutaneous cylindrical spinal cord stimulator lead implants.

BACKGROUND Stimulation-evoked discomfort secondary to ligamentum flavum stimulation (LFS) is a technological limitation of percutaneous spinal cord stimulator (SCS) lead implants. There is a paucity of literature describing the clinical presentation and time periods at which this side effect may present following insertion of cylindrical lead(s). OBJECTIVE To describe a series of 5 patients w...

متن کامل

Spinal cord toxoplasmosis as an unusual presentation of AIDS: case report and review of the literature

Approximately 10% of patients with AIDS present with some neurological deficit as their initial complaint, and up to 80% will have CNS involvement during the course of their disease. Toxoplasmosis is the most common cause of cerebral mass lesions in patients with AIDS, but appears to be an uncommon cause of spinal cord disease. The incidence of myelopathy may be as high as 20%, with 50% of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2017