Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance.

نویسندگان

  • Andrew G Elkington
  • Taigang He
  • Peter D Gatehouse
  • Sanjay K Prasad
  • David N Firmin
  • Dudley J Pennell
چکیده

PURPOSE To determine how injection rate, cardiac function, and breathhold influence the arterial input function (AIF), in order to optimize the AIF in the clinical setting for quantitative myocardial perfusion cardiovascular magnetic resonance (CMR). MATERIALS AND METHODS Gd (0.1 mmol/kg) bolus was injected at 3, 5, or 7 mL/second in 35 patients. In each cardiac cycle during the first-pass, a series of saturation recovery (SR) fast low-angle shot (FLASH) low resolution images with exponentially increasing SR delay times were acquired. Signal intensity (SI) time measurements were made from a region of interest (ROI) drawn in the ascending aorta (AA). The calculation of short T1s and thus peak Gd concentration [Gd] was performed by fitting the mean ROI SI against SR delay times. RESULTS The mean peak [Gd] in the AA increased as injection rate increased from 3 mL/second (5.0 mM), to 5 mL/second (7.1 mM), to 7 mL/second (4 mM) (P < 0.0001). The peak [Gd] increased as the left ventricular stroke volume (LV SV) increased (P = 0.01). Breath holding was not found to influence peak [Gd]. CONCLUSION In this study, we found that a high injection rate has advantages over lower injection speeds, although the duration of the AIF was apparently not significantly shortened by faster injection. The choice of expiration or inspiration as breathhold did not have a significant influence upon the AIF. Poor cardiac function was associated with a lower peak [Gd], indicating that first pass perfusion measurements in these patients will be suboptimal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment

BACKGROUND Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presen...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus

BACKGROUND Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Du...

متن کامل

Spatio-Temporal Modeling of First-Pass Perfusion Cardiovascular MRI

INTRODUCTION First-pass contrast enhanced myocardial perfusion Magnetic Resonance Imaging (MRI) is a promising technique for providing insight into how reduced coronary flow affects the myocardial tissue. It also allows the understanding of microcirculation in the myocardial tissue and myocardial angiogenesis [1]. Clinically, myocardial perfusion MRI plays a major role in the evaluation of isch...

متن کامل

Quantitative 3D Myocardial Perfusion Imaging at High Dose with Accurate Arterial Input Function Assessment

Quantitative 3D Myocardial Perfusion Imaging at High Dose with Accurate Arterial Input Function Assessment Lukas Wissmann, Markus Niemann, Robert Manka, and Sebastian Kozerke Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland, Department of Cardiology, University Hospital Zurich, Zurich, Switzerland, Division of Imaging Sciences & Biomedical Engineering, King's...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2005