A three-dimensional (3-D) point spread function (PSF) model for wide-field fluorescence microscopy, suitable for imaging samples with variable refractive index (RI) in multilayered media, is presented. This PSF model is a key component for accurate 3-D image restoration of thick biological samples, such as lung tissue. Microscope- and specimen-derived parameters are combined with a rigorous vectorial formulation to obtain a new PSF model that accounts for additional aberrations due to specimen RI variability. Experimental evaluation and verification of the PSF model was accomplished using images from 175-nm fluorescent beads in a controlled test sample. Fundamental experimental validation of the advantage of using improved PSFs in depth-variant restoration was accomplished by restoring experimental data from beads (6  μm in diameter) mounted in a sample with RI variation. In the investigated study, improvement in restoration accuracy in the range of 18 to 35% was observed when PSFs from the proposed model were used over restoration using PSFs from an existing model. The new PSF model was further validated by showing that its prediction compares to an experimental PSF (determined from 175-nm beads located below a thick rat lung slice) with a 42% improved accuracy over the current PSF model prediction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPUTATIONAL IMAGING FOR DEPTH-VARIANT FLUORESCENCE MICROSCOPY Vimeetha Myneni and Chrysanthe Preza

A key challenge in live-cell microscopy is three-dimensional (3D) low-light imaging with improved accuracy. Photon efficiency is of critical importance for live-cell imaging, where lowlight imaging is often crucial for specimen viability and fast data-acquisition. Wide-field microscopy remains the optimal methodology for harvesting the most photons in a given optical configuration efficiently. ...

متن کامل

Tomographic Phase Microscopy Quantitative 3D Imaging of Living Cells Refractive Index as an Intrinsic Source of Contrast in Light Microscopy

Most biological cells and tissues exhibit negligible absorption under visible light illumination while there are still distinctive refractive index differences among organelles, which amount to several percents relative to the mean refractive index. For this reason, the refractive index has been served as a much better source of intrinsic contrast than absorption in biological studies. Local va...

متن کامل

The point spread function of optical microscopes imaging through stratified media.

We propose a model for imaging point objects through a dielectric interface or stratified media. The model is applicable to conventional and confocal fluorescence microscopy, with single- or multiphoton excitation. An analytical solution is obtained in the form of readily computable functions. When large mismatches occur in the refractive indices of the media of the objective lens and specimen ...

متن کامل

Reducing depth induced spherical aberration in 3D widefield fluorescence microscopy by wavefront coding using the SQUBIC phase mask

Imaging thick biological samples introduces spherical aberration (SA) due to refractive index (RI) mismatch between specimen and imaging lens immersion medium. SA increases with the increase of either depth or RI mismatch. Therefore, it is difficult to find a static compensator for SA. Different wavefront coding methods have been studied to find an optimal way of static wavefront correction to ...

متن کامل

2,2'-thiodiethanol: a new water soluble mounting medium for high resolution optical microscopy.

The use of high numerical aperture immersion lenses in optical microscopy is compromised by spherical aberrations induced by the refractive index mismatch between the immersion system and the embedding medium of the sample. Especially when imaging >10 micro m deep into the specimen, the refractive index mismatch results in a noticeable loss of image brightness and resolution. A solution to this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 2015