The Effect of Heart Rate in Look-Locker Cardiac T1 Mapping

نویسندگان

  • G. S. Slavin
  • T. Song
  • J. A. Stainsby
چکیده

Introduction: Look-Locker inversion recovery produces images at multiple inversion times (TI) after a 180° inversion pulse (1). In non-cardiac and phantom experiments, the sequence timing can be carefully controlled. This allows the user to exactly specify both the TIs and the magnetization recovery time between inversions. In cardiac imaging, however, these timing variables are measured in units of the R-R interval (TRR), which in routine practice is determined by the patient’s heart rate as recorded only at the beginning of the scan. Because the heart rate can vary considerably during imaging, this heart rate dependency can result in significant errors in T1 measurements. For example, when using inversion pulses with segmented imaging, there must be a delay time Trec of up to 5 × T1 before each subsequent inversion to allow the magnetization to fully recover. If the heart rate increases, the shortened Trec will not allow full and consistent magnetization recovery. Furthermore, if there is any variation in TRR during a scan, the TIs will not occur at the nominally expected times of n × TRR, where n is heartbeat number. Both of these situations will produce errors in fitting the relaxation curve and thus in calculating T1. The goal of this work was to develop a Look-Locker sequence that will reduce the errors introduced by intrascan heart rate variations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart-rate independent myocardial T1-mapping using combined saturation and inversion preparation pulses

Background Myocardial T1 mapping remains a challenging task due to restrictions imposed by cardiac and respiratory motion. Modified Look-Locker Inversion Recovery (MOLLI) [1] is widely used for 2D cardiac T1-mapping. In MOLLI, the spin-lattice relaxation curve is sampled several times after a single magnetization preparation. The ECG triggered imaging induces a disturbance in the relaxation cur...

متن کامل

Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice

OBJECT To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. MATERIALS AND METHODS To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial a...

متن کامل

Extracellular matrix expansion by cardiac magnetic resonance T1 mapping- validation with myocardial biopsy

Background Accumulation of diffuse myocardial fibrosis / extracellular volume (ECV) in the myocardium is common to various cardiac diseases and is associated with an unfavorable prognosis. Various cardiac magnetic resonance (CMR) T1 mapping techniques have recently been proposed for the quantification of ECV, including: 1. Modified Look-Locker Inversion recovery (MOLLI) T1 mapping including cal...

متن کامل

Validation of Small-Animal Look-Locker Inversion Recovery (SALLI) Cine versus Cine MR in assessment of left ventricular function

Background Small-Animal Look-Locker Inversion Recovery (SALLI) is a novel imaging method that generates simultaneously cardiac T1 maps, cine MR and inversion recovery-prepared images for high heart rates. T1 mapping by SALLI has been tested and compared with histology, however the assessment of left ventricular (LV) function has not yet been validated. Our aim was to compare the measurement of ...

متن کامل

Effects of heart rate in modified look-locker inversion recovery (MOLLI) T1 mapping

Background MOLLI is a method of producing a T1 map at end diastole by using the electrocardiogram (ECG) under respiratory arrest to obtain consecutive inversion recovery images with an arbitrary number of MOLLI cycles. Since a variety of heart rates are presumed clinically, it is important to understand their effects on the T1 value and the error of measurement. We investigated the error of mea...

متن کامل