OBJECTIVES We investigated the biomechanical characteristics of anterior or posterior tibial tunnel placement of the soft tissue graft with a soft tissue interference screw in anterior cruciate ligament (ACL) reconstruction. METHODS Twelve bovine tibiae and digital extensor tendons were divided into two homogeneously equal groups after they were stripped of all soft tissues. Tibial tunnels were prepared and digital extensor tendons were fixed at nonanatomic (apart from the joint) anterior (n=6, group I) or posterior (n=6, group II) tibial tunnel positions with a soft tissue metal interference screw, 9x30 mm in size. All the specimens were cycled 500 times from 50 to 250 N at 1 Hz frequency in a servo hydraulic test device, after which ultimate load-at-failure testing was performed at a rate of 20 mm/min. RESULTS The mean screw insertion torque values were 8.2+/-2.4 Nm and 8.4+/-2.8 Nm in groups I and II, respectively (p=0.88). No significant differences were found between the two groups with respect to graft displacement (1.9+/-0.8 mm vs 2.3+/-0.4 mm; p=0.38) and stiffness (132.7+/-10.9 N/mm vs 126.4+/-8.5 N/mm, p=0.98) at the end of cyclic loading. CONCLUSION Our results show that the site of nonanatomic soft tissue graft fixation in the tibial tunnel (anterior or posterior) with a soft tissue interference screw do not affect the biomechanical parameters in ACL reconstruction.
منابع مشابه
Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملThe WasherLoc and Bone Dowel: A Rigid, Slippage-Resistant Tibial Fixation Device for a Soft Tissue Anterior Cruciate Ligament Graft
The WasherLoc is a tibial fixation device for soft tissue anterior cruciate ligament (ACL) reconstruction that combines superior fixation properties (945 N strength, 507 N/mm stiffness, and high resistance to slippage) with a simple surgical technique. The WasherLoc is a washer with 13 short spikes that penetrate the soft tissue ACL graft in multiple locations and 4 long peripheral spikes that ...
متن کاملCorrelation of interference screw insertion torque with depth of placement in the tibial tunnel using a quadrupled semitendinosus-gracilis graft in anterior cruciate ligament reconstruction.
PURPOSE To evaluate the insertion torque of a soft-tissue interference screw in relation to depth of insertion into the tibial tunnel when used for fixation of a quadrupled semitendinosus-gracilis autograft in anterior cruciate ligament reconstruction. TYPE OF STUDY Biomechanical cadaver study. METHODS Ten quadrupled semitendinosus-gracilis grafts were harvested from fresh-frozen cadaver kn...
متن کاملDelayed Tibial Osteomyelitis after Anterior Cruciate Ligament Reconstruction with Hamstrings Autograft and Bioabsorbable Interference Screw: A Case Report and Review of the Literature
Osteomyelitis following arthroscopically assisted anterior cruciate ligament (ACL) reconstruction has rarely been reported in the literature. We report a case of a 20-year-old female who had delayed tibial osteomyelitis and a pretibial cyst with culture-positive, oxacillin sensitive Staphylococcus epidermidis 15 months after an ACL reconstruction with hamstring autograft. Soft tissue fixation w...
متن کاملComparison of screw post fixation and free bone block interference fixation for anterior cruciate ligament soft tissue grafts: biomechanical considerations.
Endoscopic (single-incision) anterior cruciate ligament (ACL) reconstruction with bone patellar tendon bone can usually be secured with interference screws on the femur and tibia. Infrequently, patella alta, which results in a longer tendinous component of the graft construct, can result in construct mismatch, resulting in a large portion of the tibial bone plug extruding from the tibial tunnel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica et traumatologica turcica
دوره 39 5 شماره
صفحات -
تاریخ انتشار 2005