Efficacy and safety of Descemet’s membrane endothelial keratoplasty versus Descemet’s stripping endothelial keratoplasty: A systematic review and meta-analysis
نویسندگان
چکیده
PURPOSE Based on current evidence, the efficiency and safety of Descemet's membrane endothelial keratoplasty (DMEK) was compared with that of Descemet's stripping endothelial keratoplasty (DSEK). METHODS Pubmed, Embase, Web of Science, the Cochrane Database and conference abstracts were comprehensively searched for studies that compared the efficacy and safety of DMEK and DSEK. The efficacy outcome was the postoperative best-corrected visual acuity (BCVA). The safety outcomes included the postoperative endothelial cell density (ECD) and complications such as graft detachment, graft rejection, graft failure, postoperative elevated intraocular pressure (IOP), tissue loss, etc. The outcomes were pooled using random-effects models with Stata 13.0 software. Heterogeneity was qualified with Q statistic and I2/H2 statistic. Publication bias was assessed using funnel plot, Begg rank correlation test, and Egger or Horbard linear regression. RESULTS 19 articles were eligible, and 1124 eyes and 1254 eyes were included in the DMEK and DSEK groups, respectively. The overall pooled estimates showed a significantly better postoperative BCVA, a comparable ECD and an increased graft detachment rate in the DMEK group compared with the DSEK group (BCVA: mean difference (MD) = -0.15, 95% CI = -0.19 to -0.11, P<0.001; ECD: MD = 14.88, 95% CI = -181.50 to 211.27, P = 0.882; graft detachment rate: OR = 4.56, 95% CI = 2.43 to 8.58, P<0.001). Except for the postoperative ECD, which was changed to be higher in the DSEK group than the DMEK group, the learning curve did not have a marked effect on the comparison outcome of the BCVA and graft detachment rate based on the estimates pooled from studies that collected data during the DMEK learning phase (ECD (learning curve): MD = -361.24, 95% CI = -649.42 to -73.07, P = 0.014). CONCLUSION Although DMEK is a more technically difficult and challenging procedure, it may represent a safe and more efficient alternative to DSEK for the treatment of corneal endothelial diseases, even during its learning curve.
منابع مشابه
Descemet’s Stripping Automated Endothelial Keratoplasty – A Review
Descemet’s stripping automated endothelial keratoplasty (DSAEK) has become the procedure of choice to treat corneal endothelial dysfunction. The technique involves replacing the diseased host endothelium with a graft consisting of a thin layer of posterior stroma, Descemet’s membrane and endothelium. In comparison with penetrating keratoplasty (PK), DSAEK confers quicker visual and structural r...
متن کاملCataract Surgery Bonus Feature
NOVEMBER/DECEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 23 F ull-thickness penetrating keratoplasty (PKP) has been the preferred corneal transplantation technique since the procedure was first described in 1905 by Eduard Zirm.1 Today, PKP generally results in clear corneal grafts, with a graft survival rate of up to 72% at 5 years.2 However, the procedure is frequently complicated by ...
متن کاملDouble-pass microkeratome technique for ultra-thin graft preparation in Descemet’s stripping automated endothelial keratoplasty
Endothelial keratoplasty is evolving with increased attention placed on the optical qualities of the posterior donor lenticule. In efforts to improve visual outcomes, the effects of the thickness, smoothness, and planar profile are being studied. This paper describes a double-pass microkeratome technique to create ultra-thin (less than 100 μm) Descemet's stripping automated endothelial keratopl...
متن کاملPotential benefits of mathematical models to predict endothelial cell density following penetrating keratoplasty.
Endothelial cell loss following penetrating keratoplasty is progressive, with greater loss in the perioperative time period. However, we do not know why, for example, a density of 500 cells/mm stabilizes in some eyes maintaining corneal clarity, whereas a similar density in other eyes leads to late onset graft failure. Can one predict the decay of cells to explain this example? Why do we have g...
متن کاملUse of Photorefractive Keratectomy Treated Donor Corneas for Endothelial Keratoplasty
357 Corneal transplantation has been widely performed since the first successful surgery was described by Zirm. Recent data from the Eye Bank Association of America (EBAA), the accredited organization that tracks donor quality and volume of surgeries performed anually in the United States, has shown that 46,253 corneal tissues were used for transplantation in 2014 domestically while 76,431 tiss...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017