Methods for calculating coronary perfusion pressure during CPR.
نویسندگان
چکیده
Coronary perfusion pressure (CPP) is a major indicator of the effectiveness of cardiopulmonary resuscitation in human and animal research studies, however, methods for calculating CPP differ among research groups. Here we compare the 6 published methods for calculating CPP using the same data set of aortic (Ao) and right atrial (RA) blood pressures. CPP was computed using each of the 6 calculation methods in an anesthetized pig model, instrumented with catheters with Cobe pressure transducers. Aortic and right atrial pressures were recorded continuously during electrically induced ventricular fibrillation and standard AHA CPR. CPP calculated from the same raw data set by the 6 calculation methods ranged from -1 (signifying retrograde blood flow) to 26 mmHg (mean +/- SD of 15 +/- 11 mmHg). The CPP achieved by standard closed chest CPR is typically reported as 10-20 mmHg. Within a single study the CPP values may be comparable; however, the CPP values for different studies may not be a reliable indicator of the efficacy of a given CPR method. Electronically derived true mean coronary perfusion pressure is arguably the gold standard method for representing coronary perfusion pressure.
منابع مشابه
Hemodynamics in humans during conventional and experimental methods of cardiopulmonary resuscitation.
High-fidelity hemodynamic recordings of aortic and right atrial pressures and the coronary perfusion gradient (the difference between aortic and atrial pressure) were made in nine patients during cardiopulmonary resuscitation (CPR). Findings during conventional manual CPR were compared with those during high-impulse CPR (rate, 120 cycles/min with a shorter compression:relaxation ratio) as well ...
متن کاملA new cardiopulmonary resuscitation method using only rhythmic abdominal compression: a preliminary report.
This article introduces 2 new cardiopulmonary resuscitation (CPR) concepts: (1) the use of only rhythmic abdominal compression (OAC) to produce blood flow during CPR with ventricular fibrillation and (2) a new way of describing coronary perfusion effectiveness, namely, the area between the aortic and right atrial pressure curves, summed over 1 minute, the units being millimeters of mercury per ...
متن کاملCoronary perfusion pressure during cardiopulmonary resuscitation.
Currently, there is no way to measure the effectiveness of cardiopulmonary resuscitation in humans. The literature suggests that minimum aortic diastolic and estimated coronary perfusion pressures during cardiopulmonary resuscitation (CPR) in the animal model correlate with higher resuscitation rates. Six patients were studied during CPR to determine the arterial diastolic and estimated coronar...
متن کاملBeta-adrenergic blockade reduces myocardial injury during experimental cardiopulmonary resuscitation.
OBJECTIVES We attempted to determine the effects of beta-adrenergic blockade during cardiopulmonary resuscitation (CPR) on defibrillation rates and postresuscitation left ventricular function. BACKGROUND The results of previous studies suggest that propranolol administration can both reduce myocardial oxygen requirements and increase coronary perfusion pressure during CPR. METHODS Left vent...
متن کاملInspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest.
BACKGROUND Blood pressure is severely reduced in patients in cardiac arrest receiving standard cardiopulmonary resuscitation (CPR). Although active compression-decompression (ACD) CPR improves acute hemodynamic parameters, arterial pressures remain suboptimal with this technique. We performed ACD CPR in patients with a new inspiratory threshold valve (ITV) to determine whether lowering intratho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiovascular engineering
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2009