A comparison of the in vitro moisture vapour transmission rate and in vivo fluid-handling capacity of six adhesive foam dressings to a newly reformulated adhesive foam dressing.

نویسندگان

  • Cindy L Zehrer
  • David Holm
  • Staci E Solfest
  • Shelley-Ann Walters
چکیده

This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. Mean upright MVTR for the reformulated dressing was 980 g/m(2) /24 hours and was significantly different than all of the comparator dressings (P < 0·0001), which ranged from 80 to 1620 g/m(2) /24 hours (three higher/three lower). The reformulated dressing median wear time ranged from 6·1 to >7·0 days, compared with 1·0 to 3·5 days for the comparator dressings (P = 0·0012 to P < 0·0001). The median fluid volume handled ranged from 78·0 to >87 ml compared with 13·0 to 44·5 ml for the comparator dressings (P = 0·0007 to P < 0·001). Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new in vivo test method to compare wound dressing fluid handling characteristics and wear time.

A refined in vivo artificial wound model utilizing artificial wound fluid (AWF) was developed to overcome important limitations such as adhesive-skin interactions, movement, pressure, shear, and varying environmental conditions in in vitro models. Using this model, a study with primary endpoints of wear time and fluid handling capacity was conducted to compare two foam dressings: a high perform...

متن کامل

Removal of adhesive wound dressing and its effects on the stratum corneum of the skin: comparison of eight different adhesive wound dressings.

In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. V...

متن کامل

Comparison of Allevyn Adhesive and Biatain Adhesive in the management of pressure ulcers.

OBJECTIVE The primary objective was to assess dressing delamination and the ensuing potential consequences during wear and/or removal, as well as the effect of residue remaining in the ulcer following foam breakdown. METHOD In this prospective multicentre study, 32 patients with a grade II or III pressure ulcer were randomised to receive either Allevyn Adhesive or Biatain Adhesive dressing. T...

متن کامل

Evaluation of low-adherent antimicrobial dressings

Aims: To investigate the physical and antimicrobial properties of low-adherent, silver-containing gelling fibre and certain adhesive foam dressings in vitro. Methods: An in vitro model was used to quantitatively measure fibroblast adhesion to dressings in their dry and hydrated states. Microscopy techniques were used to visualise and quantify aspects of dressing composition and structure. Final...

متن کامل

Physical, morphological, and wound healing properties of a polyurethane foam-film dressing

BACKGROUND We investigated the physicochemical properties of Medifoam® N and its wound healing performance compared to other commercially available polyurethane (PU) foam dressing in vitro and in vivo to gain insight in their clinical performance. METHODS Wound contact layer and cross-section of eleven polyurethane foam dressings were assessed with field-emission scanning electron microscope....