Improved immunoradiometric assay for plasma renin.

نویسندگان

  • J Deinum
  • F H Derkx
  • M A Schalekamp
چکیده

BACKGROUND Our renin IRMA overestimated renin in plasmas with high prorenin-to-renin ratios. We suspected that the overestimation of renin was caused less by cross-reactivity of the renin-specific antibody with prorenin than by a conformational change of prorenin into an enzymatically active form during the assay. METHODS Because the inactive form of prorenin converts slowly into an active form at low temperature, we raised the assay temperature from 22 degrees C to 37 degrees C, simultaneously shortening the incubation time from 24 to 6 h. The former IRMA was performed in <1 working day with these modifications. RESULTS The comeasurement of prorenin as renin was eliminated. Reagents were stable at 37 degrees C, and the new and old IRMAs were comparable in terms of precision and accuracy. The functional lower limit of the assay (4 mU/L) was below the lower reference limit (9 mU/L). The modified IRMA agreed closely with the activities measured with an enzyme-kinetic assay. Results were not influenced by the plasma concentration of angiotensinogen. At normal angiotensinogen concentrations, the IRMA closely correlated with the classical enzyme-kinetic assay of plasma renin activity. CONCLUSION The modified IRMA, performed at 37 degrees C, avoids interference by prorenin while retaining the desirable analytical characteristics of the older IRMA and requiring less time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pathophysiological significance of plasma total renin and prorenin in patients with diabetes mellitus.

To seek the pathophysiologic significance of measuring the concentration of total renin instead of prorenin, we determined the plasma total renin concentration by immunoradiometric assay and correlated the results with various clinical features and laboratory parameters of diabetic complication in 108 patients with diabetes mellitus. The plasma prorenin concentration was estimated as the differ...

متن کامل

Two-site direct immunoassay specific for active renin.

A sensitive immunoradiometric assay, without an enzymatic step and specific for active human renin, was developed with use of two monoclonal antibodies (MAbs). In this assay system, the first MAb was coupled to magnetic beads (Magnogel); the second one, directed against the active form of the enzyme, was radiolabeled with 125I. The specificity of this assay was demonstrated in experiments measu...

متن کامل

Validation of a new automated renin assay.

BACKGROUND Measurement of plasma renin is important for the treatment of patients with congenital adrenal hyperplasia (CAH) and in the evaluation of patients with suspected hyperaldosteronism. Immunologic assays for plasma renin offer easier implementation and standardization than enzyme-kinetic assays for plasma renin activity, but their sensitivity and specificity have been questioned. We stu...

متن کامل

Clinical validation of renin monoclonal antibody-based sandwich assays of renin and prorenin, and use of renin inhibitor to enhance prorenin immunoreactivity.

Newly developed IRMAs to measure the plasma concentrations of renin and prorenin were validated for clinical use and compared with a classical enzyme kinetic assay. The IRMAs involve two monoclonal antibodies, one that reacts equally well with renin and prorenin and one that recognizes renin well but prorenin only minimally. Prorenin reactivity with the second antibody was enhanced by adding th...

متن کامل

Plasma renin activity: an assay with ongoing clinical relevance.

Featured Article: Fyhrquist F, Soveri P, Puutula L, Stenman U-H. Radioimmunoassay of plasma renin activity. Clin Chem 1976;22:250 – 6. In the early 1970s there was a growing need for reliable and clinically useful methods for the determination of the activity of the renin-angiotensin system. Bioassay methods for renin activity, although valuable in early research, were too cumbersome and unreli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1999