Failing stentless aortic valves: redo aortic root replacement or valve in a valve?

نویسندگان

  • Jonathan Finch
  • Isabelle Roussin
  • John Pepper
چکیده

OBJECTIVES Reoperation for failing stentless aortic valve replacement is a technically demanding procedure that has traditionally been tackled in one of two ways: either root replacement or the more conservative option of implanting a stented valve within the valve. We sought to determine the relative operative risks, follow-up status and medium to long-term survival of these two methods. METHODS We conducted a retrospective review of a single surgeon's experience of the two techniques over a 10-year period from 2000 to 2010. Excluding cases of active endocarditis, 110 patients were identified, of which 65 underwent 'valve-in-valve' procedures ('Group A') and 45 had redo root replacement ('Group B'). The most common bioprostheses reoperated were homografts (roots or subcoronary implants) and Toronto Stentless Porcine Valves. Aortic valve replacement alone was performed in 68% in Group A and 64% in Group B, with males comprising 75% of Group A and 82% of Group B. Average ages were 61.5 ± 14.2 years and 61.9 ± 12.1 years, respectively. RESULTS Operative and cardiopulmonary bypass durations were significantly greater for redo root procedures and correspondingly, postoperative complications were more common. Thirty-day mortality after valve-in-valve replacement was 3%, and after redo root replacement it was 11%. Despite significantly higher transvalvular gradients in Group B, the symptomatic status was equally good at 2 months, 1 year and last follow-up. At an average interval of 5.1 ± 2.7 years for Group A, survival was 83% vs 76% at 7.3 ± 2.9 years for Group B. There have been two reinterventions in Group A and 3 in Group B. Only one valve-in-valve patient has developed a paraprosthetic leak. CONCLUSIONS This retrospective review has confirmed our hypothesis that where both root diameter permits and satisfactory debridement can be performed, valve-in-valve replacement is the more conservative surgical strategy for stentless aortic valve replacement revision. Although transvalvular gradients on echocardiography are significantly higher with the introduction of a stented prosthesis, medium-term outcomes in terms of symptomatic status, late complications and reintervention rate were non-inferior. We await the medium-term results of transcatheter aortic valve implantation for the same indication with interest.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves

BACKGROUND Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aort...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Stentless aortic valve replacement: an update

Although porcine aortic valves or pericardial tissue mounted on a stent have made implantation techniques easier, these valves sacrifice orifice area and increase stress at the attachment of the stent, which causes primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability, stentless bioprostheses use was revived in the early 1990s. The purpose...

متن کامل

Stentless aortic valves. Current aspects

The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....

متن کامل

Stentless root bioprosthesis for repair of acute type A aortic dissection.

OBJECTIVE The superior hemodynamics and excellent long-term clinical performance of stentless xenografts are well described. However, the early and midterm clinical outcomes of stentless valves in patients with acute type A dissection are widely unknown. The current study evaluated the early and midterm clinical outcomes of stentless bioprosthesis for repair of acute type A aortic dissection. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 2013