A novel flexible, retrievable endovascular stent system for small-vessel anatomy: preliminary in vivo data.

نویسندگان

  • Arnd Doerfler
  • Wolfgang P H Becker
  • Isabel Wanke
  • Sophia L Goericke
  • K M Mueller
  • Nina Blechschmid
  • Achim Flesser
  • Hermann Monstadt
  • Michael Forsting
چکیده

BACKGROUND AND PURPOSE This study assessed the in vivo delivery, retrievability, short-term patency, and cellular response to a new flexible endovascular stent system in a rabbit model. The stent is designed for delivery through a microcatheter and is fully retrievable with electrolytic detachment from a delivery wire. METHODS We successfully deployed nine stents (range of sizes, 2.5-4 mm diameter, 15-35 mm length) in six straight (carotid) and three angled (subclavian) arteries of six Chinchilla Bastard rabbits. Serial imaging was performed by using intravenous digital subtraction angiography (IVDSA), contrast-enhanced MR angiography (CEMRA), time-of-flight MR angiography (TOF), and CT-angiography 3 days and 4 weeks after stent deployment. Subjects were euthenized after 4 weeks (n = 5), and stents were removed for histologic analysis. RESULTS Stent deployment was feasible in all cases. After initial deployment, all stents could be fully retrieved within the microcatheter. The detachment zone and the distal stent marker were easily visible under fluoroscopy, and final detachment occurred reliably in all cases. We observed no procedural complications. Noninvasive imaging by using IVDSA, MR angiography, and CT angiography was feasible in this stent system and demonstrated all arteries patent and not narrowed at 3 days and 4 weeks, findings that were confirmed by histologic analysis. CONCLUSION This electrolytically detachable stent is promising as a treatment for intracranial arteries, because it can be delivered through microcatheters small enough for intracranial navigation. It is fully retrievable, thus providing greater control than currently available stents. Noninvasive imaging by using IVDSA, MR angiography, and CT angiography is feasible in this stent system and may be useful for follow-up. Further long-term data are needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical thrombectomy with a self-expanding retrievable intracranial stent (Solitaire AB): experience in 26 patients with acute cerebral artery occlusion.

BACKGROUND AND PURPOSE Patients with stroke unsuitable for IV thrombolysis may be considered for endovascular revascularization, particularly when baseline imaging suggests proximal cerebral vessel occlusion associated with minimal established infarction. This retrospective review describes the use of a self-expanding retrievable intracranial stent (Solitaire AB) for thrombectomy in acute ische...

متن کامل

In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease

Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcati...

متن کامل

Treatment of wide-necked intracranial aneurysms with a self-expanding stent system: initial clinical experience.

BACKGROUND AND PURPOSE Currently available stents for intracranial use usually are balloon-expandable coronary stents that carry the risk of damaging a dysplastic segment of the artery, with potential vessel rupture. We assessed the technical feasibility and efficacy of the combined application of a flexible, self-expanding neurovascular stent and detachable coils in the management of wide-neck...

متن کامل

Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequen...

متن کامل

Endovascular treatment of cranial aneurysms with the pipeline flow-diverting stent: preliminary mid-term results.

PURPOSE We aimed to present our initial experience with a new self-expanding flow diverter device designed for wide-neck aneurysm treatment, assess its safety for intracranial deployment and efficacy of occlusion at mid-term follow-up. MATERIALS AND METHODS Forty-five consecutive patients with difficult aneurysmal anatomy underwent an endovascular treatment. Fifty-five intracranial aneurysms ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2005