Standardized patient methodology to assess refractive error reproducibility.

نویسندگان

  • Rakhee Shah
  • David F Edgar
  • Ronald Rabbetts
  • Deacon E Harle
  • Bruce J W Evans
چکیده

PURPOSE Standardized patient (SP) methodology is the gold standard for evaluating clinical practice. This approach was used to investigate the content of typical optometric eyecare in England and the reproducibility of refractive error measurement using prescriptions obtained by three SPs. METHODS The three SPs were independently examined by three to four expert optometric clinicians to obtain "benchmark" estimates of refractive error. One hundred two community optometrists consented to be visited by three SPs who were trained to provide accurate responses during the examinations. The spectacle prescriptions obtained by the SPs were analyzed for spherical equivalent refraction, spherical power and cylindrical power using astigmatic decomposition. RESULTS The spherical equivalent refractions were found to be within +/-0.25 D of the benchmark on average 81% of the time and within +/-0.50 D 97% of the time. The spherical power was within +/-0.25 D 90% of the time and within +/-0.50 D 98% of the time. The cylindrical power agreed within +/-0.25 D 93% of the time and within +/-0.50 D 100% of the time. Based on reproducibility limits data obtained for all six eyes, any two optometrists would differ in their estimation of spherical equivalent refraction by no more than 0.75 D in 95% of repeated measures. The astigmatic data (C0 and C45) show that optometrists will differ in their estimation of the C0 component by between 0.25 and 0.61 D and for the C45 component by between 0.22 and 0.47 D in 95% of repeated measures. CONCLUSIONS The agreement between our data and the results of other similar studies support the conclusions that subjective refractive findings are reproducible to approximately +/-0.75 D when performed by multiple optometrists in patients of different age groups and levels of ametropia. SPs are an effective way of measuring reproducibility of refractive error and should be considered for further comparative analysis in different age groups and different levels of ametropia.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the compensation comparison method for retinal straylight measurement: effect of patient's age on repeatability.

AIM The assessment of repeatability and reproducibility of retinal straylight measurements with the C-Quant straylight meter (Oculus AG, Germany) and the effect of patient's age on the instrument performance are tested with a series of experiments. METHODS First, 20 eyes from 20 subjects (mean age 26.9 (SD 2.7) years, mean refractive error -1.34 (2.72) D) were examined with the C-Quant strayl...

متن کامل

Reproducibility and accuracy of measurements with a hand held autorefractor in children.

AIM To determine reproducibility and accuracy of the Nikon Retinomax autorefractor when used with children who were made cycloplegic. METHODS Autorefraction and retinoscopy or subjectively refined retinoscopy (where, under the patient's direction, the refraction was varied until the best visual acuity was achieved) were performed on the right eye of 47 children, age 11-93 months. Autorefracti...

متن کامل

Measurement of refractive error in Native American preschoolers: validity and reproducibility of autorefraction.

PURPOSE To examine (1) reproducibility of cycloplegic retinoscopy (C-RNS), cycloplegic autorefraction (C-Autoref), and noncycloplegic autorefraction (NC-Autoref), and (2) validity of C-Autoref and NC-Autoref compared with C-RNS in preschoolers with astigmatism. METHODS Subjects were 36 Native American preschoolers. Three measurements of right eye refractive error were obtained with each of th...

متن کامل

Prevalence and risk factors of undercorrected refractive errors among Singaporean Malay adults: the Singapore Malay Eye Study.

PURPOSE To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. METHODS This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting an...

متن کامل

Refractive error and age-related maculopathy: the Blue Mountains Eye Study.

PURPOSE To assess associations between refractive error (hyperopia, myopia, and spherical equivalent [SEq]) and age-related maculopathy (ARM) in an older population. METHODS A population-based survey examined 3654 people aged 49 years or older, 82% of whom were permanent residents in an area west of Sydney, Australia. Participants had a detailed eye examination, including standardized refract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 86 5  شماره 

صفحات  -

تاریخ انتشار 2009