Fluoroscopic analysis of lumbar epidural contrast spread after retrograde interlaminar ventral epidural injection (RIVEI)

نویسندگان

  • Ji Seon Jeong
  • Jae Chol Shim
  • Jung Pil Woo
  • Jae Hang Shim
چکیده

BACKGROUND Retrograde interlaminar ventral epidural injection (RIVEI) may hypothetically be more effective if the catheter is placed at the ventrocaudal aspect of the exiting nerve. We tested that hypothesis by measuring ventral and dorsal epidural contrast flow during RIVEI. METHODS To perform RIVEI, a 17 G Tuohy needle was inserted to access the epidural space. A 19 G epidural catheter was inserted and advanced through the needle, passing in a caudal direction to the lower aspect of the contralateral pedicle. Fluoroscopic images were recorded at 1.5 ml increments of contrast. Based on the images of contrast dispersal, the extent of contrast spreading was assessed in 82 patients. RESULTS All 82 patients (100%) injected with 3.0 ml contrast medium demonstrated ventral epidural spreading. Mean spreading level from the catheter tip was 2.21 ± 0.93 with 3.0 ml of contrast. Spreading to the superior aspect of the supra-adjacent intervertebral disc was observed in 67/82 (81.7%) of RIVEIs with 3.0 ml of contrast injected into the ventral epidural space. We found that 3.0 ml of contrast reached the inferior aspect of the infra-adjacent intervertebral disc in 95.1% (78/82) of RIVEIs performed. CONCLUSIONS Our findings imply that a one-level RIVEI may be sufficient in situations where a two-level injection would currently be used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adding Particulate or Non-Particulate Steroids to the Local Anesthetics When Performing Parasagittal Interlaminar Epidural Injections.

We read with great interest a recent study by Ghai et al (1) wherein they followed 56 out of 69 randomized patients for 12 months following parasagittal interlaminar (PIL) injection with local anesthetics (LA) alone or LA with steroid (LS). We agree with author’s choice of technique to achieve adequate and consistent ventral epidural spread of injectate. Parasagittal interlaminar epidural stero...

متن کامل

Epidurography contrast patterns with fluoroscopic guided lumbar transforaminal epidural injections:a prospective evaluation.

BACKGROUND Lumbar transforaminal epidural injections have been utilized in the treatment of radicular pain with proven success. It was postulated that interlaminar epidural injections result in a dorsal flow of contrast while transforaminal epidural steroid injections showed good ventral flow limited to one single spinal motion segment. There have been no published studies evaluating epidurogra...

متن کامل

Inadvertent Intrafacet Injection during Lumbar Interlaminar Epidural Steroid Injection: A Comparison of CT Fluoroscopic and Conventional Fluoroscopic Guidance.

BACKGROUND AND PURPOSE Inadvertent intrafacet injection can occur during interlaminar epidural steroid injection, resulting in a false-positive loss of resistance and nontarget injection of medication. The purpose of this investigation was to compare the observed rates of this phenomenon during lumbar interlaminar epidural steroid injection performed by using conventional fluoroscopic and CT fl...

متن کامل

A complication during caudal steroid injection.

BACKGROUND AND OBJECTIVE Epidural injections in the lumbar spine are provided by caudal, lumbar interlaminar or transforaminal routes. Caudal epidural steroid injections are often used for low back pain. Fluoroscopic guidance has been frequently cited as a requirement for this procedure. In this case report, we demonstrate the importance of fluoroscopic guidance during caudal epidural injection...

متن کامل

Contrast Spread Technique: Evolution

The recognition of needle entry into an epidural space is a pivotal moment in cervical, thoracic, or lumbar epidural injections. Its significance cannot be overestimated. Regardless of how experienced you are, realizing that you are approaching an epidural space makes your heart beat faster. The safety of the procedure and its success rate depends upon proper and reliable identification of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2013