Practical Active and Semi-active Strategies for the Control of Room Acoustics in the Low Frequency Range
نویسنده
چکیده
Modal acoustics is one of the main sources of annoyance in the low frequency range in rooms. Active noise control techniques can be deployed to reach sufficient acoustic benefit, but limited to a single frequency, whereas broader efficiency would require complex systems with a large number of transducers. This paper introduces the semi-active/active concept of “electroacoustic absorbers”, which are able to handle low-frequency room acoustics problems along significant frequency bandwidth, in the experimental context of the damping of the first modal frequencies of a test chamber. This study will focus on highlighting practical advantages of such techniques when compared to active strategies (performances, stability, complexity, integration, cost,...).
منابع مشابه
Robust Identification of Smart Foam Using Set Mem-bership Estimation in A Model Error Modeling Frame-work
The aim of this paper is robust identification of smart foam, as an electroacoustic transducer, considering unmodeled dynamics due to nonlinearities in behaviour at low frequencies and measurement noise at high frequencies as existent uncertainties. Set membership estimation combined with model error modelling technique is used where the approach is based on worst case scenario with unknown but...
متن کاملOptimal Control via Integrating the Dynamics of Magnetorheological Dampers and Structures
Magnetorheological (MR) dampers have the advantage of being tuned by low voltages. This has attracted many researchers to develop semi-active control of structures in theory and practice. Most of the control strategies first obtain the desired forces of dampers without taking their dynamics into consideration and then determine the input voltages according to those forces. As a result, these st...
متن کاملINVESTIGATION OF THE OPTIMAL SEMI-ACTIVE CONTROL STRATEGIES OF ADJACENT BUILDINGS CONNECTED WITH MAGNETORHEOLOGICAL DAMPERS
This study investigates the efficacy of optimal semi-active dampers for achieving the best results in seismic response mitigation of adjacent buildings connected to each other by magnetorheological (MR) dampers under earthquakes. One of the challenges in the application of this study is to develop an effective optimal control strategy that can fully utilize the capabilities of the MR dampers. H...
متن کاملGalloping and VIV control of square-section cylinder utilizing direct opposing smart control force
An adaptive fuzzy sliding mode controller (AFSMC) is adopted to reduce the 2D flow-induced vibration of an elastically supported square-section cylinder, free to oscillate in stream-wise andtransverse directions in both lock-in and galloping regions. The AFSMC strategy consists of a fuzzy logic inference system intended to follow a sliding-mode controller (SMC), and a robust control syste...
متن کاملAn optimal semi-active thermal exchange-Fuzzy logic Controller for Structural Dynamic Control and Rehabilation
The effect of intelligent semi-active thermal exchange-fuzzy controller in structural rehabilitation by attenuating seismic responses of structural systems is investigated. In the suggested control system, MR dampers and sensors are employed as a semi-active controller. Resultant control forces of MR damper are administrated by providing external voltage supply, during the earthquakes and high ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -