Muscle function of knee extensors and flexors after stroke is selectively impaired at shorter muscle lengths.

نویسندگان

  • Astrid Horstman
  • Karin Gerrits
  • Marijke Beltman
  • Thomas Janssen
  • Manin Konijnenbelt
  • Arnold de Haan
چکیده

OBJECTIVE To investigate whether muscle strength is selectively more affected at shorter lengths of thigh muscles as result of stroke and to determine whether this is associated with impaired neural activation at shorter muscle lengths. DESIGN Case-control study. SUBJECTS Fourteen patients with sub-acute stroke, and 12 able-bodied controls. METHODS In patients (bilaterally) and able-bodied controls torque and activation was measured during maximal voluntary isometric contractions of knee extensors and flexors at 30 degrees , 60 degrees and 90 degrees knee flexion. RESULTS The paretic knee extensors showed lower normalized maximal torques (73%) and lower normalized activation (71%) compared with control at 30 degrees . The paretic knee flexors showed lower normalized maximal torques at 60 degrees (64%) and 90 degrees (45%) with non-significantly lower normalized activation (~79% and ~67%, respectively). CONCLUSION As a result of stroke, lower muscle torque at shorter muscle lengths of the knee extensors is associated with a length-dependent lower voluntary activation, which may also be the case for the flexor muscles, but not with altered co-activation. We recommend investigating the role of specific training of paretic knee extensors and flexors in especially shortened positions to improve recovery of function after stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prolonged quadriceps activity following imposed hip extension: a neurophysiological mechanism for stiff-knee gait?

The biomechanical characteristics of stiff knee gait following neurological injury include decreased knee flexion velocity at toe-off, which may be due to exaggerated quadriceps activity. The neuromuscular mechanism underlying this abnormal activity is unclear, although hyperexcitable heteronymous reflexes may be a source of impaired coordination. The present study examines the contribution of ...

متن کامل

The Effect of One Period Core Stability Eexercise with and without Kinesio Taping on Biomechanical Effective Factors in Lower Cross Syndrome on Female

The aim of this study is the effect of one period core stability exercise with and without kinesio taping on biomechanical effective factors in lower cross syndrome on female. 36 female between 30 to 40 were randomly divided in to 3 groups (control, with taping and without taping).  each group consist 12 participant. To measure Pelvic slope, Hip and Knee ROM, Isometric strength of flexors and e...

متن کامل

Effects of eccentric exercise on optimum length of the knee flexors and extensors during the preseason in professional soccer players.

OBJECTIVE To assess the effects of eccentric exercise on optimum lengths of the knee flexors and extensors during the preseason in professional soccer. DESIGN Twenty-eight athletes from a professional Spanish soccer team (Division II) were randomly assigned to an eccentric exercise intervention group (EG) or a control group (CG). Over the four-week period two athletes from the control group s...

متن کامل

The unreliability of clinical measures of muscle tone: implications for stroke therapy.

BACKGROUND the central tenet of the neurofacilitatory approach to stroke therapy is that muscle tone needs to be normal before normal movement can occur. A reliable clinical measure of the full spectrum of muscle tone is needed to test: (i) the purported relationship between muscle tone, other motor impairments and disability, and (ii) the effectiveness of stroke therapy to restore movement. ...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation medicine

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 2009