Phase retrieval using polychromatic illumination for transmission X-ray microscopy

نویسندگان

  • Yijin Liu
  • Joy C. Andrews
  • Junyue Wang
  • Florian Meirer
  • Peiping Zhu
  • Ziyu Wu
  • Piero Pianetta
چکیده

An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to moving the sample in the beam direction in order to analyze the propagation-introduced phase effect, we have illuminated the TXM using X-rays of different energy without any motor movement in the TXM system. Both theoretical analysis and experimental studies have confirmed the feasibility and the advantage of our method, because energy tuning can be performed with very high energy resolution using a double crystal monochromator at a synchrotron beam line, and there is zero motor error in TXM system in our approach. High-spatial-resolution phase retrieval is accomplished using the proposed method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reverse projection retrieval in edge illumination x-ray phase contrast computed tomography

Edge illumination (EI) x-ray phase contrast computed tomography (CT) can provide threedimensional distributions of the real and imaginary parts of the complex refractive index ( δ β = − + n 1 i ) of the sample. Phase retrieval, i.e. the separation of attenuation and refraction data from projections that contain a combination of both, is a key step in the image reconstruction process. In EI-base...

متن کامل

Edge illumination X-ray phase tomography of multi-material samples using a single-image phase retrieval algorithm.

In this paper we present a single-image phase retrieval algorithm for multi-material samples, developed for the edge illumination (EI) X-ray phase contrast imaging method. The theoretical derivation is provided, along with any assumptions made. The algorithm is evaluated quantitatively using both simulated and experimental results from a computed tomography (CT) scan using the EI laboratory imp...

متن کامل

Phase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy

PURPOSE The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. MATERIALS AND METHODS Normal mice were used for experiments. Some of the mouse lungs were prepared by the lung fixation-inflation method. The resulting sponge-like inflated lung sa...

متن کامل

Polychromatic Maximum Likelihood Reconstruction for Talbot-Lau X-ray Tomography

Compared to conventional attenuation imaging, Talbot-Lau X-ray grating interferometry applied within a polychromatic setup suffers from additional artifacts. Among those are beam hardening and dispersion effects due to the complex coupling of different physical effects involved in the image formation process. In computed tomography these effects lead to image degradation, such as cupping and st...

متن کامل

Phase imaging using a polychromatic x-ray laboratory source.

We describe a quantitative phase imaging process using an x-ray laboratory-based source with an extremely broad bandwidth spectrum. The thickness of a homogeneous object can be retrieved by using separately spectrally weighted values for the attenuation coefficient and the decrement of the real part of the refractive index. This method is valid for a wide range of object types, including object...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011