Superselective pseudocontinuous arterial spin labeling.
نویسندگان
چکیده
A new technique for the imaging of flow territories of individual extra- and intracranial arteries is presented. The method is based on balanced pseudocontinuous arterial spin labeling but employs additional time-varying gradients in between the radiofrequency pulses of the long labeling train. The direction of the additional gradient vector is perpendicular to the selected artery and its azimuthal angle is switched after every radiofrequency pulse. The phases of the radiofrequency pulses are adopted to cancel out the phase accrual of the spins at the center of the target vessel due to the extra applied gradients. This results in efficient inversion at the targeted position, whereas elsewhere time-varying phase changes will result in marginal inversion efficiency. By changing the moment of the added gradients, the size of the labeling focus can be adjusted. Influence of the temporal order of the additional gradients on the labeling efficiency and on the selectivity was investigated by simulations and experimental measurements. In a volunteer study, the acquisition of high signal-to-noise ratio flow territory images of small branches of the anterior cerebral artery distal to the circle of Willis was demonstrated. This shows the method's flexibility for dealing with complicated arterial geometries and its ability to superselectively label small intracranial arteries.
منابع مشابه
3D Pseudocontinuous Arterial Spin-Labeling MR Imaging in the Preoperative Evaluation of Gliomas.
BACKGROUND AND PURPOSE Previous studies showed conflicting results concerning the value of CBF maps obtained from arterial spin-labeling MR imaging in grading gliomas. This study was performed to investigate the effectiveness of CBF maps derived from 3D pseudocontinuous arterial spin-labeling in preoperatively assessing the grade, cellular proliferation, and prognosis of gliomas. MATERIALS AN...
متن کامل3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts.
Arterial spin labeling (ASL) is a completely noninvasive magnetic resonance imaging (MRI) perfusion method for quantitatively measuring cerebral blood flow utilizing magnetically labeled arterial water. Advances in the technique have enabled the major MRI vendors to make the sequence available to the clinical neuroimaging community. Consequently, ASL is being increasingly incorporated into the ...
متن کاملVessel-encoded arterial spin-labeling using pseudocontinuous tagging.
A new signal-to-noise ratio (SNR) efficient method is introduced for the mapping of vascular territories based on pseudocontinuous arterial spin labeling (ASL). A pseudocontinuous tagging pulse train is modified using additional transverse gradient pulses and phase cycling to place some arteries in a tag condition, while others passing through the same tagging plane are in a control condition. ...
متن کاملSupport vector machine classification of arterial volume‐weighted arterial spin tagging images
INTRODUCTION In recent years, machine-learning techniques have gained growing popularity in medical image analysis. Temporal brain-state classification is one of the major applications of machine-learning techniques in functional magnetic resonance imaging (fMRI) brain data. This article explores the use of support vector machine (SVM) classification technique with motor-visual activation parad...
متن کاملComparison of Quantitative Cerebral Blood Flow Measurements Performed by Bookend Dynamic Susceptibility Contrast and Arterial Spin-Labeling MRI in Relapsing-Remitting Multiple Sclerosis.
BACKGROUND AND PURPOSE Quantitative CBF usage as a biomarker for cognitive impairment and disease progression in MS is potentially a powerful tool for longitudinal patient monitoring. Dynamic susceptibility contrast perfusion with bookend T1-calibration (bookend technique) and pseudocontinuous arterial spin-labeling have recently been used for CBF quantification in relapsing-remitting MS. The n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 3 شماره
صفحات -
تاریخ انتشار 2010