Accuracy of the Takeda TM-2420/TM-2020 determined by the British Hypertension Society protocol.

نویسندگان

  • E O'Brien
  • F Mee
  • N Atkins
  • K O'Malley
چکیده

Results: The three recorders passed the before-use interdevice variability assessment, after which 85% of inflations recorded with these devices during the in-use phase gave valid readings, and the three devices subsequently passed the after-use interdevice variability assessment. The main validation test was carried out in 86 subjects with a wide range of pressures, the results being analysed according to a grading system from A to D. The first Takeda TM-2420 achieved D rating for both systolic and diastolic pressures. The first Takeda used in the main validation test failed to function after testing in 36 subjects and had to be replaced. The Takeda TM-2420 failed to satisfy the criteria for accuracy of the Association for the Advancement of Medical lnstrumentation (AAMI), with an average difference @s.d.) of 4 f 11 and 2 f 11 mmHg for systolic and diastolic pressure, respectively. Subject acceptability was good. The manufacturer's manual was clear and reasonably comprehensive.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the SpaceLabs 90207, Novacor DIASYS 200, Del Mar Avionics Pressurometer IV and Takeda TM-2420 ambulatory systems according to British and American criteria.

Ambulatory blood pressure measurement, which has been confined to research for many years, is now an accepted investigation in clinical practice [ l ] . In an effort to ensure that the devices meet the requirements of clinical practice the British Hypertension Society (BHs) has published a comprehensive protocol for the evaluation of blood pressure measuring devices with special reference to am...

متن کامل

Twenty-four-hour ambulatory blood pressure monitoring: a review of validation data.

As the clinical applications for 24-h ambulatory blood pressure monitoring expand, market demands increase, and there are now at least 13 manufacturers producing elaborate and expensive systems for recording 24-h ambulatory pressures. It is often difficult to assess the accuracy and performance characteristics of these devices and failure to standardize validation makes it difficult to compare ...

متن کامل

Ambulatory blood pressure measurement in the diagnosis and management of hypertension.

Before the diagnostic potential of 24-hour non-invasive BP measurement can be assessed, the accuracy of ambulatory recorders must be established, and normal reference values determined. The accuracy criteria of four ambulatory BP measuring systems (the SpaceLabs 90207, the Novecor DIASYS 200, the Takeda TM-2420 and the Del Mar Avionics Pressurometer IV) have been assessed according to the Briti...

متن کامل

State of the market. A review of ambulatory blood pressure monitoring devices.

The introduction of 24-hour ambulatory blood pressure measurement into clinical practice created a large market for ambulatory blood pressure measurement devices. Forty-three such devices from 31 manufacturers or suppliers are now available to satisfy a market demand that is likely to increase. The aim of this article is to identify the devices available and then to examine critically any valid...

متن کامل

Validation of TM-2655 oscillometric device for blood pressure measurement.

OBJECTIVE To perform validation for an arm-type oscillometric TM-2655 device (A&D Company Ltd, Tokyo, Japan) for blood pressure measurement according to the British Hypertension Society protocol. METHODS Eighty-five study participants (33 men and 52 women) were included in the study. Mean age was 52.9+/-15.0 years, systolic blood pressure range was 84-208 mmHg and diastolic blood pressure ran...

متن کامل