Monitoring Fluctuations at a Synchrotron Beam-line Using Matched Ion Chambers: 2. Isolation of Component Noise Sources, and Application to Attenuation Measurements Showing Increased Precision by Two Orders of Magnitude
نویسندگان
چکیده
The significance of statistical fluctuations in a synchrotron beam is often neglected, with a consequent loss of precision or accuracy of up to two orders of magnitude. We illustrate this for the specific example of an X-ray attenuation measurement. Since all X-ray measurements involve either scattering or absorption (or both), the net potential gain in precision is similar for all such experiments, including crystallographic and XAFS determinations. We demonstrate the net gain with data obtained with two matched ion chambers on a monochromatised bending magnet beam at the Photon Factory, Tsukuba. Isolating and measuring component contributions to the overall fluctuations allows a robust determination of the limiting experimental precision. This approach also determines the absolute incident flux without measuring the absolute photon count. The type of statistical analysis described is not only a post-facto diagnostic tool but, by being incorporated into the experiment on-line, can provide a real-time optimising intervention in the measurement process.
منابع مشابه
Preliminary Characterization Tests of Detectors of on-Line Monitor Systems of the Italian National Center of Oncological Hadron-Therapy (CNAO)
Introduction Hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. The Italian National Center of Oncological Hadron-therapy (CNAO) has been realized as the first facility in Italy to treat very difficult tumors with protons and Carbon ions. The on-line monitor system for CNAO has been developed by the Department of Physics of the Univers...
متن کاملCVD diamond-based semi-transparent beam-position monitors for synchrotron beamlines: preliminary studies and device developments at CEA/Saclay.
Polycrystalline diamond synthesized using the chemical vapour deposition (CVD) technique can be used to fabricate new types of photodetectors for the characterization of X-ray light in synchrotron beamlines. Since diamond exhibits a low absorption to low-energy photons, such devices allow beam-position monitoring with very little beam attenuation at photon energies as low as 2 keV up to 15-20 k...
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کاملIonization Chamber Detector for X-ray with Beam Position Monitoring
Ionization Chambers have been commonly used at beamlines in many synchrotron radiation facilities. Typical ADC ion chambers are pictured in Figure 1. The chambers generate a current proportional to the incident X-ray beam intensity. The ionization chamber allows users to determine the change in beam position in a single axis by comparing two signals that are created as the beam passes through t...
متن کاملInterpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001