Measuring Dose and Response with Multivariate Data

نویسنده

  • Paul D. Sampson
چکیده

How to relate two blocks of variables? Partial least squares Analysis two-block pls u, v u'u = v'v = 1 Low-dimensional representation of the pattern of correlations/ covariances between two blocks of variables: A second dimension can be computed as directions orthogonal to the first ones, accounting for the second most correlation/covariance. A direction in each of the two data spaces, for which the correlation/covariance between them is a maximum. PLS usually better interpretable than CCA

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of adaptive response of gamma radiation in the operating room personnel exposed to anesthetic gases by measuring the expression of Ku 80, Ligase1 and P53 genes

Introduction: Staffs of operating room are continuously exposed to anesthetic gases and                                                       ionizing radiation. Adaptive response, as a defense mechanism, will occur when cells become exposed to a low dose of factors harming DNA that causes in the next exposures to higher doses o...

متن کامل

Assessment of Adaptive Response of Gamma Radiation in the Operating Room Personnel Exposed to Anesthetic Gases by Measuring the Relative Gene Expression Changes Ku80, Ligase1 and P53

Background: Some operating room personnel are occupationally exposed to genotoxic agents such as anesthetic gases and ionizing radiation. Adaptive response, as a defense mechanism, will occur when cells become exposed to a low dose of factors harming DNA (priming dose), which in the subsequent exposure to higher dose of those factors (challenging dose), show more resistance and sensibility.. <b...

متن کامل

The microscopic dose enhancement factor measurment of bismuth nanoparticles in external radiation therapy using MRI polymer gel dosimetery

Introduction: Bismuth-based nanoparticles having high atomic number and electron density, besides of being utilized as CT contrast agent, stand as a strongly proposed method for dose enhancement in radiotherapy. Embedded nanoparticle in polymer gel dosimeter poses the first step to assess the dose enhancement capability in nanoparticles. To this end, MAGICA gel dosimeter, whic...

متن کامل

Estimation of the benchmark dose by structural equation models.

While epidemiological data typically contain a multivariate response and often also multiple exposure parameters, current methods for safe dose calculations, including the widely used benchmark approach, rely on standard regression techniques. In practice, dose-response modeling and calculation of the exposure limit are often based on the seemingly most sensitive outcome. However, this procedur...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012