Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

نویسندگان

  • C J Harvey
  • M J O'Doherty
  • C J Page
  • S H Thomas
  • T O Nunan
  • D F Treacher
چکیده

BACKGROUND Several factors have been identified which improve nebulised aerosol delivery in vitro. One of these is the addition of a spacer to the ventilator circuit which improves aerosol delivery from a jet nebuliser to a model lung by approximately 30%. The current study was designed to demonstrate whether similar improvements could be demonstrated in vivo. METHODS Ten patients (seven men) were studied during mechanical ventilation (Siemens Servo 900C) after open heart surgery. Aerosol was delivered using a Siemens Servo 945 nebuliser system (high setting) driving a System 22 Acorn jet nebuliser (Medic-Aid) containing 3 ml technetium-99m labelled human serum albumin (99mTc-HSA (50 micrograms); activity in the first nebulisation, 90 MBq; in the second nebulisation, 185 MBq). Central and peripheral lung aerosol deposition and the time to complete deposition were measured using a gamma camera and compared when the nebuliser was connected to the inspiratory limb using a simple T-piece or a 600 ml spacer. RESULTS The addition of the spacer increased total lung deposition (mean (SD) percentage initial nebuliser activity) from 2.2 (0.7)% to 3 (0.8)%. There was no difference in the time required to complete nebulisation (18.2 min v 18.3 min respectively for T-piece and spacer) or in the retention of activity in the nebuliser (46.2% v 47.1% respectively). CONCLUSIONS The combination of a spacer with a jet nebuliser increased lung deposition by 36% in mechanically ventilated patients and is a simple way of increasing drug deposition or reducing the amount of an expensive drug required for nebulisation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary deposition of a nebulised aerosol during mechanical ventilation.

BACKGROUND There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation. METHOD...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.

Increased delivery of aerosol to a model lung (attached to a mechanical ventilator) has been demonstrated with an ultrasonic nebulizer as compared to a jet nebulizer. This study examined whether the increased aerosol deposition with an ultrasonic nebulizer could also be demonstrated in vivo. Seven patients (6 male and 1 female) were studied during mechanical ventilalion (Siemens Servo 900C, Mid...

متن کامل

Nebulisation of surfactants in an animal model of neonatal respiratory distress.

AIMS To evaluate pulmonary deposition and gas exchange following nebulisation of two surfactants by either a jet or an ultrasonic nebuliser. METHOD After bronchoalveolar lavage (BAL), 19 rabbits were ventilated in four groups. Group A1 (n = 5) and A2 (n = 6) received Technetium-99m labelled Exosurf, and groups B1 (n = 4) and B2 (n = 4) received radiolabelled Survanta. Groups A1 and B1 receive...

متن کامل

Randomised crossover trial of salbutamol aerosol delivered by metered dose inhaler, jet nebuliser, and ultrasonic nebuliser in chronic lung disease.

AIMS To compare the efficacy of salbutamol delivered by metered dose inhaler (MDI), jet nebuliser, and ultrasonic nebuliser in ventilated infants with chronic lung disease. METHODS Twenty preterm ventilated infants with chronic lung disease were enrolled in two studies. In study 1 (n = 10), each infant was given 200 micrograms of salbutamol at 4 hour intervals and in random sequence from a me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 1995