Low flow, minimal flow and closed circuit system inhalational anesthesia in modern clinical practice

نویسندگان

  • MARCO VECIL
  • FRANCESCA ZORZI
  • MASSIMILIANO SALTARINI
چکیده

Low, minimal flow and closed circuit anesthesia has been pursued since the beginning of the history of anesthesia. For many decades this form of anesthesia has been restricted to devoted enthusiasts and those very fond of gas kinetics. For most clinicians, selecting a fresh flow gas higher than 3-5 L/min was widely accepted as a routine anesthesia technique. The introduction onto the market of new volatile agents as well as advanced anesthesia machines accompanied by highly reliable monitoring systems, made minimal flow or closed system anesthesia feasible on a daily basis. Clinical, cultural, environmental, pharmacological, technological and economic reasons, force the modern anesthesiologist to reconsider the role of minimal flow and closed circuit volatile anesthesia, in clinical practice. This paper analyses the main advantages offered by these anesthesia techniques. AMATO DE MONTE ( )• MARCO VECIL • CRISTINA DI STEFANO •

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Reminder to Anesthesiologists: Low-Flow Anesthesia Anestezistlere Bir Hatırlatma: Düşük Akımlı Anestezi

DOI: 10.4328/JCAM.3880 Received: 13.09.2015 Accepted: 06.10.2015 Published Online: 16.10.2015 Corresponding Author: Yeliz Kılıç, Clinic of Anesthesiology and Reanimation, Oncology Training and Research Hospital, Ankara, Turkey. GSM: +905053573180 E-Mail: [email protected] Scientific letter Although many modern anesthesia machines are suitable for using minimal/low-flow anesthetic techniq...

متن کامل

Effect of Charcoal Filter on the Emergence from Sevoflurane Anesthesia in a Semi-Closed Rebreathing Circuit

PURPOSE A charcoal filter attached within the anesthetic circuit has been shown to efficiently adsorb halothane or isoflurane, thus hastening anesthetic recovery in low or minimal flow system. This study was intended to demonstrate whether the charcoal filter enhances the recovery time from sevoflurane anesthesia using a semi-closed circuit system. MATERIALS AND METHODS Thirty healthy patient...

متن کامل

Safety and Consumption of Sevoflurane Versus Desflurane Using Target Controlled Anesthesia in Children

Background: Recently a concept of target controlled inhalational anesthesia (TCA) is introduced in which the fresh gas flow and its composition are automatically delivered to the patients with the least possible flow. The aim of this study was to compare safety, consumption and cost of both sevoflurane and desflurane when delivered by TCA using closed circuit anesthesia. Patient and Method: Six...

متن کامل

Delivery of heliox with a semi-closed circuit during spontaneous breathing: a comparative economic theoretical study

BACKGROUND Heliox is a mixture of oxygen and helium which reduces airway resistance in patients with airway obstruction. In clinical practice, patients breathing spontaneously receive heliox via an open circuit. Recently, a semi-closed circuit for heliox administration has been proposed which minimizes consumption of heliox and therefore cost of the heliox therapy; although, the semi-closed cir...

متن کامل

Inhaled anesthetics: an historical overview.

Inhalational agents have played a pivotal role in anesthesia history. The first publicly demonstrated anesthetic of the modern era, diethyl ether, was an inhalational anesthetic. The attributes of a good agent, ability to rapidly induce anesthesia, with limited side effects has led research efforts for over a hundred and fifty years. The explosion hazard was largely conquered with the developme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008