Circadian variation of blood pressure and the vascular response to asynchronous stress.

نویسندگان

  • Anne M Curtis
  • Yan Cheng
  • Shiv Kapoor
  • Dermot Reilly
  • Tom S Price
  • Garret A Fitzgerald
چکیده

The diurnal variation in the incidence of myocardial infarction and stroke may reflect an influence of the molecular clock and/or the time dependence of exposure to environmental stress. The circadian variation in blood pressure and heart rate is disrupted in mice, Bmal1(-/-), Clock(mut), and Npas2(mut), in which core clock genes are deleted or mutated. Although Bmal1 deletion abolishes the 24-h frequency in cardiovascular rhythms, a shorter ultradian rhythm remains. Sympathoadrenal function is disrupted in these mice, which reflects control of enzymes relevant to both synthesis (phenylethanolamine N-methyl transferase) and disposition (monoamine oxidase B and catechol-O-methyl transferase) of catecholamines by the clock. Both timing and disruption or mutation of clock genes modulate the magnitude of both the sympathoadrenal and pressor but not the adrenocortical response to stress. Despite diurnal variation of catecholamines and corticosteroids, they are regulated differentially by the molecular clock. Furthermore, the clock may influence the time-dependent incidence of cardiovascular events by controlling the integration of selective asynchronous stress responses with an underlying circadian rhythm in cardiovascular function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circadian variation in ischemic threshold. A mechanism underlying the circadian variation in ischemic events.

BACKGROUND There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest coronar...

متن کامل

A Mechanism Underlying the Circadian Variation in Ischemic Events

Background. There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest corona...

متن کامل

Ischemic Threshold A Mechanism Underlying the Circadian Variation in Ischemic Events

Background. There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest corona...

متن کامل

Genetic components of the circadian clock regulate thrombogenesis in vivo.

BACKGROUND Myocardial infarction, stroke, and sudden death undergo diurnal variation. Although genes relevant to hemostasis and vascular integrity undergo circadian oscillation, the role of the molecular clock in thrombotic events remains to be established. METHODS AND RESULTS A diurnal variation in the time to thrombotic vascular occlusion (TTVO) subsequent to a photochemical injury was obse...

متن کامل

Evaluation of Diameter Changes, Stress-strain Elastic Modulus and Stiffness in Normal and Atherosclerotic Common Carotid Arteries in Both Sex Based on End Pressure Variation

Evaluation of elastic properties of major arteries is subject of great interest with respect to the development of vascular diseases. In this study changes in diameter and cross-sectional area, stress-strain elastic modulus and stiffness of the common carotid arteries in healthy and atherosclerotic women and men were evaluated by using indirect end pressure changes. Variations in diameter and c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 104 9  شماره 

صفحات  -

تاریخ انتشار 2007