Creatine measurement in serum and urine with an automated enzymatic method.
نویسنده
چکیده
I describe an automated enzymatic procedure to quantitate creatine in both serum and urine. In this assay, which requires no pretreatment of the sample, creatine kinase (CK; EC 2.7.3.2) and pyruvate kinase (EC 2.1.7.40) are used as auxiliary enzymes and lactate dehydrogenase (EC 1.1.1.27) is used in the indicator reaction. CK is also used as the starting reagent. Data obtained with the present method for creatine measurement in serum were compared with those from the Jaffé method and an enzymatic method: y = 1.13x - 7.58, SE = 4.48, and r = 0.925 (Jaffé); and y = 1.17x + 2.73, SE = 5.06, and r = 0.962 (enzymatic); for creatine measurement in urine: y = 0.63x + 39.74, SE = 296.7 and r = 0.719 (Jaffé). The present method provides improved precision: the total CVs for serum, determined by the present and comparative methods, respectively, were 3.5-8.9%, 8.2-43.0%, and 5.3-16%; for urine, the CVs were 3.3-5.1% and 9.6-21.2% for the present and comparative method, respectively. I established the normal reference interval as 13-74 and 13-89 mumol/L for creatine in serum, and as 175-700 and 150-1200 mumol/24 h for creatine in urine for men and women, respectively.
منابع مشابه
Enzymatic rate assay of creatinine in serum and urine.
A two-step method for assaying creatinine in serum and urine samples, suitable with automated analyzers, is reported. Reagent 1, for the first step, contains a blanking system [creatine amidinohydrolase (CRTase), urease, glutamate dehydrogenase, NADPH, and 2-oxoglutarate] and a NADPH-regenerating system [Mg(2+)-dependent isocitrate dehydrogenase (ICD), MgCl2, and excess isocitrate]. Reagent 2, ...
متن کاملCreatine and creatine kinase measurement.
*Many methods for measuring creatine are known, the principal ones being direct calorimetric assay (l), indirect calorimetric assay (2), and destruction with bacterial adaptive enzymes (3). However, none of these methods are specific nor are they sensitive enough to detect very small amounts of creatine. rIhese assays have been used to examine urine and serum for creatine content, but, because ...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملQuantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening
In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...
متن کاملEnzymatic method for determination of inorganic phosphate in serum and urine with a centrifugal analyzer.
We describe an enzymatic method for determining inorganic phosphate in serum and urine, with use of the “CentrifiChem.” The sample is mixed with a combined enzyme-substrate system consisting of the enzymes phosphorylase a, phosphoglucomutase, and glucose-6-phosphate dehydrogenase, the coenzyme NADP, the substrate glycogen, and adenosine 5’-monophosphate as the activator for phosphorylase. The i...