Addendum to the AAPM's TG-51 Protocol for Clinical Reference Dosimetry of High-Energy Photon Beams.

نویسندگان

  • Malcolm McEwen
  • Larry DeWerd
  • Geoffrey Ibbott
  • David Followill
  • David W O Rogers
  • Stephen Seltzer
  • Jan Seuntjens
  • Toru Kawachi
  • Tetsurou Katayose
  • Takumi Kodama
  • Ryouhei Miyasaka
چکیده

An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocol's implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed. Finally, the consistency of experimental determination of ND,w coefficients is discussed. It is expected that the implementation of this addendum will be straightforward, assuming that the user is already familiar with TG-51. The changes introduced by this report are generally minor, although new recommendations could result in procedural changes for individual users. It is expected that the effort on the medical physicist's part to implement this addendum will not be significant and could be done as part of the annual linac calibration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of AAPM Addendum to TG‐51, IAEA TRS‐398, and JSMP 12: Calibration of photon beams in water

The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recom...

متن کامل

Comparison of the recommendations of the AAPM TG‐51 and TG‐51 addendum reference dosimetry protocols

This work quantified differences between recommendations of the TG-51 and TG-51 addendum reference dosimetry protocols. Reference dosimetry was performed for flattened photon beams with nominal energies of 6, 10, 15, and 23 MV, as well as flattening-filter free (FFF) beam energies of 6 and 10 MV, following the recommendations of both the TG-51 and TG-51 addendum protocols using both a Farmer® i...

متن کامل

AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.

A protocol is prescribed for clinical reference dosimetry of external beam radiation therapy using photon beams with nominal energies between 60Co and 50 MV and electron beams with nominal energies between 4 and 50 MeV. The protocol was written by Task Group 51 (TG-51) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved ...

متن کامل

Air Kerma Based Dosimetry versus Absorbed Dose to Water Based Dosimetry for High-energy Photon

Introduction: In the last 5 years the American Association of Physicists in Medicine Task Group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA...

متن کامل

Differences in electron beam dosimetry using two commercial ionization chambers and the TG‐21 protocol: Another reason to switch to TG‐51

Two of the most popular dosimetry systems used for calibration of megavoltage photon and electron beams in radiation therapy are (i) cylindrical Farmer-type chambers in liquid water and (ii) Holt Memorial parallel-plate chambers in clear polystyrene. Since implementation of the AAPM TG-21 calibration protocol, the Radiological Physics Center (which uses the Farmer in-water system) has compared ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics

دوره 37 1  شماره 

صفحات  -