Design and Development of Low Cost, Simple, Rapid and Safe, Modified Field Kits for the Visual Detection and Determination of Arsenic in Drinking Water Samples

نویسندگان

  • Jyotsna Cherukuri
  • Y. Anjaneyulu
چکیده

Arsenic is naturally found in surface and ground waters and the inorganic forms of arsenic are the most toxic forms. The adverse health effects of arsenic may involve the respiratory, gastrointestinal, cardiovascular, nervous, and haematopoietic systems. Arsenic contamination in drinking water is a global problem widely seen in Bangladesh and West Bengal of the Indian sub continent. As there is a great demand for field test kits due to the anticipated reduction of the US EPA arsenic standard from 50ppb to 10ppb a field kit which offers rapid, simple and safe method for precise estimation of arsenic at 10ppb in drinking water samples is developed. Field methods, based on the mercuric-bromide-stain, consist of three different major parts, which are carried out stepwise. The first part of the procedure is to remove serious interference caused by hydrogen sulphide. In commercially available kits either the sulphide is oxidized to sulphate and the excess oxidizing reagent removed prior to the hydride generation step or, the hydrogen sulphide is filtered out by passing the gas stream through a filter impregnated with lead acetate during the hydride generation step. The present method employs cupric chloride in combination with ferric chloride or Fentonis reagent for the removal of hydrogen sulphide, which is rapid, simple and more efficient. Other interferences at this step of the analyses are normally not expected for drinking water analysis. In the second step, the generation of the arsine gas involves the classical way of using zinc metal and hydrochloric acid, which produce the enascenti hydrogen, which is the actual reducing agent. Hydrochloric acid can be replaced by sulfamic acid, which is solid and avoids a major disadvantage of having to handle a corrosive liquid in the field. The arsine gas produces a yellowish spot on the reagent paper. Depending on the arsenic content, either, Yellow n H (HgBr)2 As (10-50ppb), Brown n (HgBr)3 As (50-100ppb) or Black n Hg3 As2 (>100ppb) are formed which can be precisely estimated by visual comparison with standard color chart. The results obtained by field kits agree well with the data obtained through I.C.P.AES methods. The most important characteristic for field measurement is that analytical results can be obtained on the site where the sample is taken with high precision and can be conveniently utilized for monitoring arsenic rapidly in a highly contaminated large geographical area.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of arsenic concentration and physiochemical characteristics of water samples from Babagorgor fountain

Since Babagorgorfountain in the Ghorveh city of Kurdistan province is located in the arsenic belt of Iran, to raise awareness about the quality of drinking water from this fountain the concentration of arsenic and other heavy metals as well as other physicochemical parameters were investigated to protect the public health. In this study, water samples were collected from Babagorgorfountain. Ars...

متن کامل

بررسی میزان آرسنیک در آب شرب: یک مطالعه موردی

Background and Objectives: Conducted studies about arsenic have shown that consumption of water contaminated with arsenic can causes different adverse health effects in consumers. World Health Organization (WHO) has enacted 10µg/L arsenic in drinking water as a guideline value. Regarding some reports about arsenic presence in a village of Hashtrood county and related health effects and also con...

متن کامل

Determination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design

The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...

متن کامل

Voltammetric Determination of Curcumin in Spices using Platinum Electrode Electrochemically Modified with Poly(Vanillin-co-Caffeic Acid)

In this study a simple, highly sensitive, and selective electrochemical method was developed for determination of the low concentration curcumin (CUR) using a poly(vanillin-co-caffeic acid) p(Van-CA) modified platinum electrode. Electrode modification was carried out electrochemically with cyclic voltammetry (CV) method. For this purpose; a solution of 6 mM vanillin (Van) and 6 mM caff...

متن کامل

Rapid determination of methanol in herbaceous distillates for their safety evaluation by a new modified chromotropic acid method

All sophisticated methods for direct determination of methanol require advanced instruments and high technical knowledge which preparing them is very expensive in none developed and developing countries. This work reports a simple and efficient qualitative technique for semi determination of methanol content in herbal distillates by a new modified chromotropic acid method. The technique is base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2005