Defective recovery of QT dispersion following transcatheter aortic valve implantation: frequency, predictors and prognosis

نویسندگان

  • Rutger-Jan Nuis
  • Gokhan Turgut
  • Robert M van der Boon
  • Nicolas M van Mieghem
  • Sjoerd T Nauta
  • Patrick W Serruys
  • Ron T van Domburg
  • Giulio Zuchelli
  • Luc Jordaens
  • Peter P de Jaegere
چکیده

BACKGROUND Corrected QT dispersion (cQTD) has been correlated with non-uniform ventricular repolarisation and increased mortality. In patients with aortic stenosis, cQTD has been shown improved after surgical valve replacement, but the effects of transcatheter aortic valve implantation (TAVI) are unknown. Therefore, we sought to explore the frequency, predictors and prognostic effects of defective cQTD recovery at 6 months after TAVI. METHODS A total of 222 patients underwent TAVI with the Medtronic-CoreValve System between November 2005 and January 2012. Patients who were on class I or III antiarrhythmics or on chronic haemodialysis or who developed atrial fibrillation, a new bundle branch block or became pacemaker dependent after TAVI were excluded. As a result, pre-, post- and follow-up ECG (median: 6 months) analysis was available in 45 eligible patients. Defective cQTD recovery was defined as any progression beyond the baseline cQTD at 6 months. RESULTS In the 45 patients, the mean cQTD was 47 ± 23 ms at baseline, 45 ± 17 ms immediately after TAVI and 40 ± 16 ms at 6 months (15% reduction, P = 0.049). Compared to baseline, cQTD at 6 months was improved in 60% of the patients whereas defective cQTD recovery was present in 40%. cQTD increase immediately after TAVI was an independent predictor of defective cQTD recovery at 6 months (per 10 ms increase; OR: 1.89, 95% CI: 1.15-3.12). By univariable analysis, defective cQTD recovery was associated with late mortality (HR: 1.52, 95% CI: 1.05-2.17). CONCLUSIONS Despite a gradual reduction of cQTD after TAVI, 40% of the patients had defective recovery at 6 months which was associated with late mortality. More detailed ECG analysis after TAVI may help to avoid late death.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmural dispersion of repolarization: a complementary index for cardiac inhomogeneity

To the editor  We read the article written by Nuis, et al. The authors investigated the effects of transcatheter aortic valve implantation (TAVI) on corrected QT dispersion (cQTD) in severe aortic stenosis patients. They concluded that, 40% of patients had defective cQTD recovery at six months after the procedure and this was associated with increased late mortality risk. We would like to cont...

متن کامل

Short-term effect of transcatheter aortic valve implantation on QT dispersion.

BACKGROUND/AIM Electrophysiological changes are observed following mechanical stretches due to pressure overload in patients with severe aortic stenosis (AS). The electrical instability occurs after depolarization and dispersion of repolarization. The aim of this study was to evaluate changes in ventricular repolarization following transcatheter aortic valve implantation (TAVI). MATERIALS AND...

متن کامل

Risk factors for paravalvular leak after transcatheter aortic valve implantation

Many studies have shown that transcatheter aortic valve implantation (TAVI) improves outcomes in patients with severe aortic stenosis in whom a classical surgical procedure cannot be performed due to the high risk. As one of the most frequent periprocedural complications of TAVI, paravalvular leak significantly affects the short- and long-term prognosis for patients undergoing implantation. In ...

متن کامل

In-hospital and mid-term predictors of mortality after transcatheter aortic valve implantation: data from the TAVI National Registry 2010-2011.

INTRODUCTION AND OBJECTIVES The treatment of severe symptomatic aortic stenosis has been revolutionized by the technique of transcatheter valve replacement. The purpose of this study was to present the outcomes and predictors of mortality in patients enrolled between 2010 and 2011 in the Transcatheter Aortic Valve Replacement National Registry. METHODS We collected 131 preprocedural, 31 perip...

متن کامل

Effect of transcatheter aortic valve implantation on QT dispersion in patients with aortic stenosis

BACKGROUND QT dispersion (QTd) is a predictor of ventricular arrhythmia. Ventricular arrhythmia is an important factor influencing morbidity and mortality in patients with aortic stenosis. Surgical aortic valve replacement reduced the QTd in this patients group. However, the effect of transcatheter aortic valve implantation (TAVI) on QTd in patients with aortic stenosis is unknown. The aim of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015