Critical analysis of ineffective post implantation implantable cardioverter-defibrillator-testing

نویسندگان

  • Markus Roos
  • J Christoph Geller
  • Marc-Alexander Ohlow
چکیده

AIM To test of the implantable-cardioverter-defibrillator is done at the time of implantation. We investigate if any testing should be performed. METHODS All consecutive patients between January 2006 and December 2008 undergoing implantable cardioverter-defibrillator (ICD) implantation/replacement (a total of 634 patients) were included in the retrospective study. RESULTS Sixteen patients (2.5%) were not tested (9 with LA/LV-thrombus, 7 due to operator's decision). Analyzed were 618 patients [76% men, 66.4 + 11 years, 24% secondary prevention (SP), 46% with left ventricular ejection fraction (LVEF) < 20%, 56% had coronary artery disease (CAD)] undergoing defibrillation safety testing (SMT) with an energy of 21 + 2.3 J. In 22/618 patients (3.6%) induced ventricular fibrillation (VF) could not be terminated with maximum energy of the ICD. Six of those (27%) had successful SMT after system modification or shock lead repositioning, 14 patients (64%) received a subcutaneous electrode array. Younger age (P = 0.0003), non-CAD (P = 0.007) and VF as index event for SP (P = 0.05) were associated with a higher incidence of ineffective SMT. LVEF < 20% and incomplete revascularisation in patients with CAD had no impact on SMT. CONCLUSION Defibrillation testing is well-tolerated. An ineffective SMT occurred in 4% and two third of those needed implantation of a subcutaneous electrode array to pass a SMT > 10 J.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Systematic Review of Defibrillation Threshold Testing at De Novo Implantation.

BACKGROUND Recent results from the largest multicenter randomized trial (Shockless IMPLant Evaluation [SIMPLE]) on defibrillation threshold (DFT) testing suggest that while shock testing seems safe, it does not reduce the risk of failed shocks or prolong survival. A contemporary systematic review of DFT versus no-DFT testing at the time of implantable cardioverter-defibrillator implantation was...

متن کامل

Importance of exercise testing shortly after subcutaneous implantable cardioverter-defibrillator implantation in patients with Brugada syndrome – The first case of associated inappropriate shock in Japan

We report the case of a 51-year-old patient with Brugada syndrome (BrS) who experienced inappropriate shock due to T-wave oversensing (TWOS) during exercise when the optimal sensing vector was selected based on the automatic analysis by a subcutaneous implantable cardioverter-defibrillator (S-ICD). After selecting another vector during exercise testing, TWOS did not re-occur. Selection of appro...

متن کامل

Success of Device-Based Methods for Atrial Tachyarrhythmia Induction during Implantation of an Implantable Cardioverter Defibrillator with Atrial Therapy

In addition to standard ventricular therapy, cardioversion using an implantable cardioverter defibrillator (ICD) with atrial therapy is one of the many new options available for treating atrial tachyarrhythmias. New data suggest that shock efficacy for AF depends on identifying atrial defibrillation thresholds (DFT) and programming the first atrial shock to at least two times the atrial DFT [1]...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017