European Community Respiratory Health Survey calibration project of dosimeter driving pressures.

نویسندگان

  • R J Ward
  • C Ward
  • D P Johns
  • B Skoric
  • M Abramson
  • E H Walters
چکیده

Two potential sources of systematic variation in output from Mefar dosimeters, the system used in the European Community Respiratory Health Survey (ECRHS) study have been evaluated: individual nebulizer characteristics and dosimeter driving pressure. Output variation from 366 new nebulizers produced in two batches for the second ECRHS were evaluated, using a solute tracer method, at a fixed driving pressure. The relationship between dosimeter driving pressure was then characterized and between-centre variation in dosimeter driving pressure was evaluated in an Internet-based survey. A systematic difference between nebulizers manufactured in the two batches was identified. Batch one had a mean+/-SD output of 7.0+/-0.8 mg x s(-1) and batch two, 6.3+/-0.7 mg x s(-1) (p<0.005). There was a wide range of driving pressures generated by Mefar dosimeters as set, ranging between 70-245 kPa, with most outside the quoted manufacturer's specification of 180+/-5%. Nebulizer output was confirmed as linearly related to dosimeter driving pressure (coefficient of determination (R2)=0.99, output=0.0377 x driving pressure-0.4151). The range in driving pressures observed was estimated as consistent with a variation of about one doubling in the provocative dose causing a 20% fall in forced expiratory volume in one second. Systematic variation has been identified that constitutes potentially significant confounders for between-centre comparisons of airway responsiveness in the European Community Respiratory Health Survey, with the dosimeter driving pressure representing the most serious issue. This work confirms the need for appropriate quality control of both nebulizer output and dosimeter driving pressure, in laboratories undertaking field measurements of airway responsiveness. In particular, appropriate data on driving pressures need to be collected and factored into between-centre comparisons. Comprehensive collection of such data to optimize quality control is practicable and has been instigated by the organizing committee for the European Community Respiratory Health Survey II.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A critical evaluation of the Mefar dosimeter.

Multicentre studies of airway responsiveness (AR) are increasingly important tools in asthma epidemiology. Because comparisons of AR are made between centres it is essential that measurement techniques are accurate and standard. This study investigated the Mefar dosimeter which is currently used in the 35 centre European Community Respiratory Health Survey (ECRHS) with the next phase currently ...

متن کامل

Variation in bronchial responsiveness in the European Community Respiratory Health Survey (ECRHS).

Attempts to compare bronchial responsiveness between populations have been hampered by between-study differences in the pharmacological agent of provocation, the method of administration and the summary statistic employed. The European Community Respiratory Health Survey used methacholine challenge delivered by Mefar dosimeter according to a standardized protocol used in 35 centres in 16 countr...

متن کامل

Variation in nebulizer aerosol output and weight output from the Mefar dosimeter: implications for multicentre studies.

The active aerosol component of nebulizers is less than 100% of output by weight, and may vary between nebulizers in different batches from the same manufacturer. A measure of bronchial responsiveness to methacholine, which can overcome this problem, is required. One hundred and sixty nebulizers from 21 centres in the European Community Respiratory Health Survey (ECRHS) were calibrated for aero...

متن کامل

A new method for measuring aerosol nebulizer output using radioactive tracers.

Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizer output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Outp...

متن کامل

Potential of phenothiazine as a thin film dosimeter for UVA exposures.

The research reported in this paper on the changes in absorbance and the calibration of a proposed UVA (320-400 nm) dosimeter have established the phenothiazine-mylar combination as a potential UVA dosimeter for population studies of UVA exposures. The change in optical absorbance at 370 nm was employed to quantify the UVA exposures. This change starts to saturate at a change in absorbance of a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2002