Prevalence of bacterial contamination of glucose test strips in individual single-use packets versus multiple-use vials.
نویسندگان
چکیده
BACKGROUND Glucose measurement is the cornerstone of diabetes control. In the hospital setting, the same device and package of test strips (50 or 100 strips) can be used to monitor glucose in several patients, which can increase cross contamination. The objective of our study is to measure bacterial contamination in glucose test strips, comparing results in individual single-use packets (one hospital) versus multi-use vials (two hospitals) in Spain. METHODS Test strips were collected from five different wards. Each hospital also collected two unopened vials from a single ward as controls. They were sent to a reference laboratory for microbiologic study. A number equal or higher than two colony forming units per strip was considered as a positive result. RESULTS Out of 423 glucose test strips collected and cultured, 146 were contaminated (34%); only 7% of individually packed strips were contaminated versus 45% of strips packed in multi-use vials, with a high statistical significance (p < .001). CONCLUSIONS In the strips from multi-use vials, a high contamination rate was found and highly pathogenic organisms were identified, such as methicillin-resistant Staphylococcus epidermidis or Staphylococcus hemolyticus. In contrast, in strips packed individually, there was a much lower contamination rate and no such pathogen organisms were found. Therefore, in the hospital setting, the use of blood glucose test strips in individual packages would be more advantageous (mainly from a clinical point of view, but also from a financial one) than those packed in multi-use vials.
منابع مشابه
Multicenter evaluation of bacterial contamination of glucose test strips.
In the U.S., healthcare-associated infections lengthen the average hospital stay by up to 19 days and increase costs by approximately $43,000 per hospitalization [1]. The prevalence of blood contamination of hospital glucose meters has been reported to be 30.2±17.5%; an increase in the number of operators increases the odds of contamination [2]. Blood glucose monitoring devices have been associ...
متن کاملBacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کاملBacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کاملThe bacterial contamination rate of glucose meter test strips in the hospital setting
OBJECTIVES To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. METHODS This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saud...
متن کاملInfection Transmission Associated with Point of Care Testing and the Laboratory’s Role in Risk Reduction
Lack of knowledge and confusion exists regarding safe and appropriate use of blood glucose monitoring equipment. Increasing numbers of diabetics, and exponential growth in blood glucose monitoring presents increased opportunities for infection transmission between patients. Diabetics have increased exposure to blood and blood borne pathogens from frequent blood glucose monitoring. Risk factors ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2013