Highly Undersampled 3D Golden Ratio Radial Imaging with Iterative Reconstruction

نویسندگان

  • M. Doneva
  • H. Eggers
  • J. Rahmer
  • P. Börnert
  • A. Mertins
چکیده

Introduction Compressed Sensing (CS) [1,2] suggests that using nonlinear reconstruction algorithms based on convex optimization an accurate signal reconstruction can be obtained from a number of samples much lower than required by the Nyquist limit. Recently, CS was demonstrated for MR imaging from undersampled data [3, 4]. Prerequisites for a good image reconstruction are the image compressibility and the incoherence of the sampling scheme. To exploit the full potential of CS, measurement samples should be acquired at random. However, random sampling of the k-space is generally impractical. Variable density sampling schemes (radial, spiral) lead to incoherent aliasing and are also advantageous because of their higher sampling density about the k-space origin, where most of the signal energy is contained. 3D variable density sampling is potentially appropriate for CS, because the noise-like aliasing is distributed within the complete volume, allowing high undersampling factors. Image reconstruction from a low number of measurements could be very useful for dynamic 3D imaging, to reduce the often long acquisition times and thus improve temporal resolution in 3D MRI. In this work, we demonstrate the applicability of CS for 3D dynamic imaging using highly undersampled 3D radial acquisition with golden ratio profile ordering [5,6]. Methods A 3D radial sequence [7] was applied that aims for a quasi-isotropic distribution of radial profiles in 3D k-space over the total duration of a scan as well as over an arbitrary time window extracted from a scan for dynamic imaging. This is achieved by using 2D golden ratios α = 0.4656 and β = 0.6823 [8] to calculate the increments Δkz = 2α and Δφ = 2πβ (Fig. 1) for successively measured projections. The isotropic distribution of profiles over time was used to perform dynamic imaging, by reconstructing images from small sections of the data (frames), during which dynamic changes are considered to be negligible. Conventional gridding reconstruction of undersampled 3D radial data often leads to images in which the imaged object is visible, but compromised by aliasing artifacts. To improve the image quality, images for each frame were iteratively reconstructed, solving the constrained optimization problem

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D Undersampled Golden-Radial Phase Encoding Using Iterative Reconstructions and Inherent Regularization

INTRODUCTION: The reconstruction of sensitivity–encoded non–Cartesian undersampled MRI has been facilitated by the use of iterative techniques [1]. However, the ill-conditioning of the associated inverse problem produces residual aliasing and noise amplification. A proven approach to stabilize the reconstruction and to diminish these effects is the use of explicit regularization methods [2-3], ...

متن کامل

Accelerating dual cardiac phase images using undersampled radial phase encoding trajectories.

A three-dimensional dual-cardiac-phase (3D-DCP) scan has been proposed to acquire two data sets of the whole heart and great vessels during the end-diastolic and end-systolic cardiac phases in a single free-breathing scan. This method has shown accurate assessment of cardiac anatomy and function but is limited by long acquisition times. This work proposes to accelerate the acquisition and recon...

متن کامل

Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI.

PURPOSE To develop a fast and flexible free-breathing dynamic volumetric MRI technique, iterative Golden-angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden-angle radial sampling. METHODS Radial k-space data are acquired continuously using the golden-angle scheme and sorted into time series by grouping an arbitrary number of consecutive sp...

متن کامل

Split Bregman multicoil accelerated reconstruction technique: A new framework for rapid reconstruction of cardiac perfusion MRI.

PURPOSE Rapid reconstruction of undersampled multicoil MRI data with iterative constrained reconstruction method is a challenge. The authors sought to develop a new substitution based variable splitting algorithm for faster reconstruction of multicoil cardiac perfusion MRI data. METHODS The new method, split Bregman multicoil accelerated reconstruction technique (SMART), uses a combination of...

متن کامل

3D Dynamic Contrast-Enhanced Using Undersampled Golden-Radial Phase Encoding

INTRODUCTION: 3D Time-Resolved Dynamic Contrast Enhanced MRI (DCE-MRI) is an important tool to depict anatomic and dynamic information (bolus pass) of thoracic vessels. The current limitation of this application is the requirement of both high spatial and temporal resolution. Several methods have been proposed to overcome this problem [1-3], however, these techniques usually need an accurate ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007