Reduced radiation exposure of the female breast during low-dose chest CT using organ-based tube current modulation and a bismuth shield: comparison of image quality and radiation dose.

نویسندگان

  • Yoon Kyung Kim
  • Yon Mi Sung
  • Jin Ho Choi
  • Eun Young Kim
  • Hyung Sik Kim
چکیده

OBJECTIVE The objective of our study was to evaluate the effect of organ-based tube current modulation and bismuth shielding on image quality and breast radiation dose in women undergoing low-dose chest CT. SUBJECTS AND METHODS From March 2011 through July 2011, 80 women prospectively underwent low-dose chest CT to screen for lung cancer. The patients were randomly assigned to a control group (n = 20), organ-based tube current modulation group (n = 20), breast shield group (n = 20), or breast shield plus organ-based tube current modulation group (n = 20). Axial slice images of the aortic arch, carina, and inferior pulmonary vein were used to analyze image quality. Three radiologists scored the image quality in terms of artifact and noise and then characterized the overall image quality as optimal (does not affect the diagnostic accuracy) or suboptimal (affects the diagnostic accuracy). Noise levels were measured in the anterior and posterior lung in each image. A phantom dose study was conducted to measure radiation dose. RESULTS Images with artifacts or noise were more frequently obtained in the breast shield groups; however, the overall image quality was not significantly different among the four groups. Measured noise levels in the anterior lung were significantly higher in the breast shield groups than the control group; however, no statistical significance was found among the four groups with regard to noise level in the posterior lung. In the phantom dose study, a 16-37.5% dose reduction in the breast was achieved using the breast shield, organ-based tube current modulation protocol, or both. CONCLUSION The radiation dose in the female breast may be reduced using a breast shield or organ-based tube current modulation during low-dose chest CT with acceptable image quality. The use of organ-based tube current modulation reduced the radiation dose in the breast without inducing image quality deterioration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Designing and construction of breast shields using silicone composite of Bismuth for chest CT

Background: Bismuth composites are new and non-lead shields that are capable of breast dose reduction while preserving image quality. In this study, different percentages of Bismuth were used in designing and constructing polymer composites as breast shields in chest CT.  Materials and Methods: Micro particles of Bismuth with a ratio of 1% to 15% in Silicone matrix with two thicknesses were use...

متن کامل

Comparing X-ray dose reduction capability of silicon-bismuth micro- and nanocomposite shields using chest CT test

Comparison of radiation shields of different thicknesses and structures (especially different particle sizes of their constituents) is helpful to select an appropriate shield for patient protection in medical imaging tests particularly CT-scan. In this study micro- and nano-powders of bismuth were mixed with silicone matrix to make composite radiation shields for breast. The shields were provid...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 200 3  شماره 

صفحات  -

تاریخ انتشار 2013