Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves.

نویسندگان

  • Willem Flameng
  • Marie-Christine Herregods
  • Monique Vercalsteren
  • Paul Herijgers
  • Kris Bogaerts
  • Bart Meuris
چکیده

BACKGROUND Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. METHODS AND RESULTS In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient- and valve-related variables revealed that P-PtM and label size </=21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). CONCLUSIONS These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valvular Heart Disease Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves

Background—Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results—In 564 patients (mean age, 74 5 years) receiving an aortic valve bioprosthesis, clinical follo...

متن کامل

Is it the time to reconsider the choice of valves for cardiac surgery: mechanical or bioprosthetic?

Valvular heart disease is a pathologic process involving one or more of the four valves (aortic, pulmonary, mitral and tricuspid) of the heart typified by stenosis or regurgitation and leading to patient symptoms. The most common causes are tissue degeneration, rheumatic fever and congenital heart diseases. Aortic valve replacement (AVR) using either mechanical or bioprosthetic (tissue) valves ...

متن کامل

Factors Determining Patient-Prosthesis Mismatch after Aortic Valve Replacement – A Prospective Cohort Study

OBJECTIVE "Patient-prosthesis mismatch" (PPM) after aortic valve replacement (AVR) has been reported to increase morbidity and mortality. Although algorithms have been developed to avoid PPM, factors favouring its occurrence have not been well defined. DESIGN AND SETTING This was a prospective cohort study performed at the Medical University of Vienna. PATIENTS 361 consecutive patients who ...

متن کامل

Choice of prosthetic heart valve for adult patients.

This review summarizes the major long-term (> or =10 to 15 years) patient outcomes after insertion of many Food and Drug Administration approved prosthetic heart valves (PHV). Mechanical PHV was associated with a better survival (p < 0.02) at 15 years after aortic valve replacement (AVR) than with a bioprosthesis in the Department of Veterans Affairs (DVA) trial. In both the DVA and the Edinbur...

متن کامل

Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

OBJECTIVE We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 121 19  شماره 

صفحات  -

تاریخ انتشار 2010