Determination of derivatized urea in exhaled breath condensate by LC-MS.

نویسندگان

  • Zhe Quan
  • Christine Purser
  • Rodney C Baker
  • Terry Dwyer
  • Rajesh Bhagat
  • Yinghong Sheng
  • Jerzy R Leszczynski
چکیده

Elevation in one or more compounds in exhaled breath condensate (EBC) has been reported to be related to one or another lung disease. The increased concentration might be caused by increased chemicals in the airway surface liquid. However, it might also be due to an increased delivery of liquid samples into the airstream. Being evenly distributed throughout the body, urea is a likely candidate for a marker of such dilution. A liquid chromatography-tandem mass spectrometry method was developed for determination of EBC urea. Urea in EBC samples was converted to 2-hydroxypyrimidine (2-HPM) through a one step reaction, along with (15)N(2)-urea added as an internal standard. The product ion m/z 97/42 was selected for quantification with m/z 99/43 from (15)N(2)-2-HPM as a standard. Concentrations of urea in EBC from five lung cancer patients were found to be 35.1, 2.2, 103.5, 19.3, and 3.6 microM, respectively. The highest values were in patients dying of respiratory distress, whose lungs were filled with fluid. Lower values were seen in patients whose conditions were improving. Lately, one of the low EBC urea values was observed in a patient whose airway status did not contribute to his poor clinical condition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LC-ESI-MS/MS method for oxidative stress multimarker screening in the exhaled breath condensate of asbestosis/silicosis patients.

The sensitive assay method was developed for a parallel, rapid and precise determination of the most prominent oxidative stress biomarkers: 8-iso-prostaglandin F(2α) a lipid oxidation biomarker, o-tyrosine an amino acid oxidation biomarker and 8-hydroxy-2'-deoxy-guanosine a nucleic acid oxidation biomarker. The method consisted of a pre-treatment part, freeze drying (lyophilization), serving th...

متن کامل

سنجش نشانگر زیستی IL-6در هوای بازدمی با استفاده از دستگاه جمع‌آورنده میعانات بازدمی

Background and Objective: The collection of exhaled breath condensate (EBC) is a noninvasive, safe and simple technique to obtain direct samples from lung and use for estimation of the effects of air pollution on human subjects. EBC contains several compounds including simple ions, hydrogen peroxide, proteins, cytokines, deoxyribonucleic acid (DNA), creatine, Electrolytes, trace elements and to...

متن کامل

Methadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment

Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...

متن کامل

Methadone concentrations in exhaled breath condensate, serum and urine of patients under maintenance treatment

Drug abuse is a serious problem causing health, economical and psycho-social negative outcomes. Methadone is commonly used drug for management of drug addiction. Exhaled breath condensate (EBC) is a promising non-invasive biological sample which attracted more attention in recent years. This work aimed to extend the applicability of a developed preconcentration – liquid chromatographic method f...

متن کامل

Profiling the Proteome of Exhaled Breath Condensate in Healthy Smokers and COPD Patients by LC-MS/MS

Three pools of exhaled breath condensate (EBC) from non-smokers plus healthy smokers (NS + HS, n = 45); chronic obstructive pulmonary disease (COPD) without emphysema (COPD, n = 15) and subjects with pulmonary emphysema associated with α(1)-antitrypsin deficiency (AATD, n = 23) were used for an exploratory proteomic study aimed at generating fingerprints of these groups that can be used in fu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2010