Prospective Motion Correction with Stereoscopic Optical Tracking at 7T
نویسندگان
چکیده
INTRODUCTION Artifacts caused by motion during the image acquisition are a well known problem at 1.5T and 3T. In high field systems such as 7T the available signal to noise ratio leads to potentially higher resolution than in systems with lower field. Unfortunately higher resolution requires longer acquisition times without patient motion. Therefore an increased need for motion correction exists. Prospective motion correction [1] for 3T systems addresses motion during the measurement and promises to improve image quality in high resolution acquisitions. In this study an implementation of prospective motion correction on a 7T MR scanner is presented and the correction of a moving phantom and of a test person are described for different image resolutions.
منابع مشابه
Highest Resolution In Vivo Human Brain MRI Using Prospective Motion Correction
High field MRI systems, such as 7 Tesla (T) scanners, can deliver higher signal to noise ratio (SNR) than lower field scanners and thus allow for the acquisition of data with higher spatial resolution, which is often demanded by users in the fields of clinical and neuroscientific imaging. However, high resolution scans may require long acquisition times, which in turn increase the discomfort fo...
متن کاملOptical Motion Tracking With Two Markers for Robust Prospective Motion Correction
single-marker tracking and (b) adaptive tracking with 2 markers. If marker 1 becomes obscured, the algorithm switches to marker 2 (if visible) to reconstruct the location of marker 1 and provide correct feedback. 3744 Optical Motion Tracking With Two Markers for Robust Prospective Motion Correction Aditya Singh, Benjamin Zahneisen, Brian Keating, Michael Herbst, Maxim Zaitsev, and Thomas Ernst ...
متن کاملComparison of Image-Based Retrospective and Optical Prospective Motion Correction for Diffusion Tensor Imaging
INTRODUCTION Correction of rigid head motion correction is important in diffusion tensor imaging because of the long acquisition times. Rigid head correction can be carried out either retrospectively prospectively. In this study, we compared the effectiveness of these two approaches in correcting motion artifacts in DTI. Retrospective correction was based on MR-based navigator data (1-3), whils...
متن کاملMR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI
Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging usin...
متن کاملImproved Prospective Optical Motion Correction for DTI Using an Extended-Field-of-View and Self-Encoded Marker
INTRODUCTION – Due to the prolonged acquisition time, correction for rigid-body motion artifacts is essential for diagnostic image quality in DTI. Prospective motion correction using a monovision camera system and a checkerboard marker has previously been used to correct for rigid head motion artifacts [1,2]. In this study, we use a more sophisticated marker design to improve prospective optica...