Manual and automated instrumentation for identification of Enterobacteriaceae and other aerobic gram-negative bacilli.
نویسنده
چکیده
Identification of gram-negative bacilli, both enteric and nonenteric, by conventional methods is not realistic for clinical microbiology laboratories performing routine cultures in today's world. The use of commercial kits, either manual or automated, to identify these organisms is a common practice. The advent of rapid or "spot" testing has eliminated the need for some commonly isolated organisms to be identified with the systems approach. Commercially available systems provide more in-depth identification to the species level as well as detect new and unusual strains. The answers obtained from these systems may not always be correct and must be interpreted with caution. The patient demographics, laboratory workload and work flow, and technologist's skill levels should dictate the system of choice. Cost considerations introduce another variable into the equation affecting choice. Each system has its own strengths and weaknesses, and each laboratory must decide on the level of sophistication that fulfills its particular needs.
منابع مشابه
Preliminary evaluation of the autoSCAN-3, an instrument for automated reading an interpretation of microdilution trays: identification of aerobic gram-negative bacilli.
The autoSCAN-3, an instrument for the automated reading and interpretation of Microscan microdilution trays, was evaluated for its ability to identify gram-negative bacilli. The results obtained by the visual reading of microdilution trays were compared with the results obtained with the machine. A total 387 clinical isolates of Enterobacteriaceae and nonfermenters were compared by both methods...
متن کاملCollaborative evaluation of the Radiometer Sensititre AP80 for identification of gram-negative bacilli.
A multicenter trial of the Sensititre AP80 panel read on the Sensititre AutoReader (Radiometer America, Westlake, Ohio) for the automated identification of gram-negative bacilli was conducted with 1,023 clinical isolates (879 members of the family Enterobacteriaceae plus 144 nonenteric organisms). Assignment of taxa was based on the computer-assisted interpretation of the results of a series of...
متن کاملBiodegradation of Jet Fuel by Three Gram Negative Bacilli Isolated from Kerosene Contaminated Soil
Petroleum hydrocarbon contamination is a major global prevalent issue in the petroleum sector. This research focuses on evaluating biodegradation of three Gram-negative bacilli, isolated from cowpea planted soil, contaminated with kerosene. The Gram negative bacilli strains have been characterized and identified, using MicrobactTM ID24E systems for the identification of Enterobacteriaceae and c...
متن کاملEvaluation of the VITEK 2 system for rapid identification of medically relevant gram-negative rods.
The new VITEK 2 system (bioMérieux) was evaluated at two independent sites with the identification card for gram-negative bacilli (ID-GNB card). Of the 845 strains tested, which represented 70 different taxa belonging to either the family Enterobacteriaceae or the nonenteric bacilli, 716 (84.7%) were correctly identified at the species level. Thirty-two (3.8%) additional strains were identified...
متن کاملBiodegradation of Jet Fuel by Three Gram Negative Bacilli Isolated from Kerosene Contaminated Soil
Petroleum hydrocarbon contamination is a major global prevalent issue in the petroleum sector. This research focuses on evaluating biodegradation of three Gram-negative bacilli, isolated from cowpea planted soil, contaminated with kerosene. The Gram negative bacilli strains have been characterized and identified, using MicrobactTM ID24E systems for the identification of Enterobacteriaceae and c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical microbiology reviews
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2005