Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia.
نویسندگان
چکیده
BACKGROUND Respiratory rate should be monitored continuously in the post-anaesthesia care unit (PACU) to avoid any delay in the detection of respiratory depression. Capnometry is the standard of care but in extubated patients requires a nasal cannula or a face mask that may be poorly tolerated or can be dislodged, leading to errors in data acquisition and false alarms. The value of a new non-invasive acoustic monitor in this setting has not been fully investigated. METHODS Adult patients admitted to the PACU after general anaesthesia were included. After tracheal extubation, an adhesive sensor with an integrated acoustic transducer (RRa™) was placed on the patient's throat and connected to its monitor while the patient breathed through a face mask with a carbon dioxide sampling port (Capnomask™) connected to a capnometer. Both the acoustic monitor and the capnometer were connected to a computer to record one pair of data per second for up to 60 min. RESULTS Fifty-two patients, mean (range) age 54 (22-84) yr and BMI 26 (19-39) kg m(-2), were studied. Compared with capnometry, the bias and limits of agreement of the acoustic method were 0 (-1.4-1.4) bpm. The acoustic sensor was well tolerated while the face mask was removed by eight patients, leading to study discontinuation in two patients. CONCLUSIONS In extubated patients, continuous assessment of respiration rate with an acoustic monitor correlated well with capnometry.
منابع مشابه
Accuracy of acoustic respiration rate monitoring in pediatric patients.
BACKGROUND Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. OBJECTIVE We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. METHODS Continuous respiration r...
متن کاملEfficiency and outcome of non-invasive versus invasive positive pressure ventilation therapy in respiratory failure due to chronic obstructive pulmonary disease
Background: Application noninvasive ventilation in the patients with exacerbation of chronic obstructive pulmonary disease (COPD) reduced mortality. This case-control study was designed to compare efficiency and outcome of non-invasive (NIV) versus invasive positive pressure ventilation (IPPV) in respiratory failure due to COPD Methods: The patients were assigned to NIV or IPPV intermittantl...
متن کاملNew modalities for non-invasive positive pressure ventilation: A review article
Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...
متن کاملInvestigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement.
BACKGROUND Arterial pressure (AP) monitoring should be accurate, easy to use, free of risks, and ideally continuous. The continuous non-invasive arterial pressure (CNAP) device is non-invasive and provides continuous pressure readings. This study was performed to compare the agreement of CNAP and invasive AP monitoring. METHODS Ninety patients undergoing surgery under general anaesthesia were...
متن کاملNon-Invasive Determination of Blood Glucose Levels by Optical Waveguide
Objective: Today, there are various non-invasive techniques available for the determination of blood glucose levels. In this study, the level of blood glucose was determined by developing a new device using near-infrared (NIR) wavelength, glass optical waveguide, and the phenomenon of evanescent waves. Materials and Methods: The body's interstitial fluid has made possible the development of ne...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 108 5 شماره
صفحات -
تاریخ انتشار 2012