Inferior glenosphere placement reduces scapular notching in reverse total shoulder arthroplasty.

نویسندگان

  • Xinning Li
  • Joshua S Dines
  • Russell F Warren
  • Edward V Craig
  • David M Dines
چکیده

Scapular notching is a common complication after reverse shoulder arthroplasty and has been associated with poor clinical outcomes. Factors associated with notching include neck shaft angle and glenosphere position. The goal of this study was to evaluate the incidence of notching with an eccentric glenosphere that allows for inferior offset as well as its effect on clinical outcome. The charts of 82 patients who underwent reverse shoulder arthroplasty with this eccentric glenosphere were retrospectively reviewed. Scapular notching was assessed with standard anteroposterior radiographs of the glenohumeral joint according to the Nerot-Sirveaux classification system. Two experienced observers evaluated all radiographs. The presence of radiolucent lines was also evaluated. Both range of motion (ROM) and Constant-Murley scores were obtained. Average age was 74 years (range, 61-91 years), and follow-up was 26.3 months (range, 19-39 months). According to the Nerot-Sirveaux classification, 73 (89%) had no notching, 5 (6%) had grade I notching, 2 (2.5%) had grade II notching, and 2 (2.5%) had grade III notching. The overall presence of notching was 11% and correlated to the amount of inferior offset. No radiolucent lines were seen around the prosthesis. Both ROM and Constant-Murley scores (from 31.3 to 74.2) improved significantly in all patients from preoperative evaluation to final follow-up (P<.05). No significant differences in ROM and functional outcome were seen between the groups with and without notching. The inferior offset glenosphere created with this glenosphere base plate design reduced the incidence of scapular notching in reverse shoulder arthroplasty. This was particularly true when the glenosphere was maximally offset inferiorly. In the short term, notching does not affect ROM or functional outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective study of scapular notches in reverse shoulder arthroplasties.

We conducted a retrospective study of 36 patients with reverse shoulder prostheses to assess whether placement of the glenoid component affected development of scapular notches. Minimum follow-up was 2 years. Glenosphere position and its relation to scapular notching was analyzed radiographically. The glenosphere overhung the inferior glenoid rim in 19 cases (52.8%) and was flush with the rim i...

متن کامل

Comparison of Clinical and Radiological Results according to Glenosphere Position in Reverse Total Shoulder Arthroplasty: A Short-term Follow-up Study

BACKGROUND In a previous biomechanical study, eccentric glenospheres with more inferior position of the center of rotation were shown to improve range of motion and reduce the incidence of scapular notching after reverse total shoulder arthroplasty (RSA). The purpose of this study was to compare the clinical and radiological results of RSA using an eccentric glenosphere to those using a concent...

متن کامل

Late-Onset, Advanced Scapular Notching Associated with a Lateral Offset Reverse Arthroplasty Design - A Case Report

Reverse shoulder arthroplasty, introduced by Grammont et al. [1] in 1987, is commonly associated with scapular notching, [2] an impingement of the humeral cup against the scapula’s inferior border. Although the clinical significance of notching has been debated, 2 studies reported less successful clinical outcomes in its presence [2,3]. A laboratory study showed that a varus humeral neck-shaft ...

متن کامل

Anterior and Posterior Scapular Impingement Associated with Two Different Reverse Shoulder Designs

Introduction Reverse shoulder arthroplasty is an increasingly popular treatment option for cuff tear arthropathy and other degenerative conditions of the glenohumeral joint that have been previously treated with limited success. Concerns about scapular notching have driven design and surgical technique modifications by manufacturers and surgeons in order to improve range of motion (ROM) and sta...

متن کامل

Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis

BACKGROUND AND PURPOSE Despite good clinical results with the reverse total shoulder arthroplasty, inferior scapular notching remains a concern. We evaluated 6 different solutions to overcome the problem of scapular notching. METHODS An average and a "worst case scenario" shape in A-P view in a 2-D computer model of a scapula was created, using data from 200 "normal" scapulae, so that the pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 38 2  شماره 

صفحات  -

تاریخ انتشار 2015