Successful transcatheter closure of a residual patent ductus arteriosus with complex anatomy after surgical ligation using an amplatzer ductal occluder guided by live three-dimensional transesophageal echocardiography.

نویسندگان

  • Yi Cheng Chuang
  • Wei-Hsian Yin
  • Ming C Hsiung
  • Shen Kou Tsai
  • Kuo Chen Lee
  • Hsin-Ju Huang
  • Ching-Huei Ou
  • Chung-Yi Chang
  • Jeng Wei
  • Yi-Pen Chou
چکیده

Residual patent ductus arteriosus (PDA) after surgical ligation is not common, but the anatomy of the residual duct may be distorted by the surgical ligation resulting in a difficult transcatheter closure. Such distorted anatomy of the duct may not be demonstrated by the two-dimensional transesophageal echocardiography (2D TEE). Fortunately, live 3D TEE provided the precise anatomy of the elongated distorted residual duct, and as in the case presented herein, guided the Amplatzer ductal occluder (ADO). We concluded that live 3D TEE provided novel images of complex residual ducts and successful guidance of a ductal occluder.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...

متن کامل

Transcatheter Closure of Large Patent Ductus Arteriosus Using the Amplatzer Ductal Occluder

Background: Coils are suitable for the closure of a small patent ductus arteriosus (PDA) but are not recommended for a large PDA. We reported our initial experience of transcatheter closure of a large PDA using the Amplatzer ductal occluder (ADO). Methods: From April 2002 to October 2006, all patients with ductal size greater than 3.5 mm undergoing transcatheter closure of PDA using the ADO wer...

متن کامل

Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder.

The Amplatzer duct occluder (ADO) (AGA Medical Corp., Golden Valley, MN) is designed to meet criteria for an optimal transcatheter technique for closure of a patent ductus arteriosus. It was developed as an alternative to surgical closure and other interventional techniques. It is not technically complex, allows controlled deployment, is retrievable and repositionable, and has a low risk of emb...

متن کامل

Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

OBJECTIVE Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). METHODS From May 2004 to Septem...

متن کامل

Transcatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.

OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Echocardiography

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2011