Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser.

نویسندگان

  • A A Kosterev
  • R F Curl
  • F K Tittel
  • C Gmachl
  • F Capasso
  • D L Sivco
  • J N Baillargeon
  • A L Hutchinson
  • A Y Cho
چکیده

A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining Biogenic Content of Biogas by Measuring Stable Isotopologues 12CH4, 13CH4, and CH3D with a Mid-Infrared Direct Absorption Laser Spectrometer

A tunable laser absorption spectrometer (TLAS) was developed for the simultaneous measurement of δ13C and δD values of methane (CH₄). A mid-infrared interband cascade laser (ICL) emitting around 3.27 µm was used to measure the absorption of the three most abundant isotopologues in CH₄ with a single, mode-hop free current sweep. The instrument was validated against methane samples of fossil and ...

متن کامل

A Quantum Cascade Laser-Based Optical Sensor for Continuous Monitoring of Environmental Methane in Dunkirk (France)

A room-temperature continuous-wave (CW) quantum cascade laser (QCL)-based methane (CH4) sensor operating in the mid-infrared near 8 μm was developed for continuous measurement of CH4 concentrations in ambient air. The well-isolated absorption line (7F2,4 ← 8F1,2) of the ν4 fundamental band of CH4 located at 1255.0004 cm(-1) was used for optical measurement of CH4 concentration by direct absorpt...

متن کامل

Monolithically, widely tunable quantum cascade lasers based on a heterogeneous active region design

Quantum cascade lasers (QCLs) have become important laser sources for accessing the mid-infrared (mid-IR) spectral range, achieving watt-level continuous wave operation in a compact package at room temperature. However, up to now, wavelength tuning, which is desirable for most applications, has relied on external cavity feedback or exhibited a limited monolithic tuning range. Here we demonstrat...

متن کامل

Feasibility of 13CO2 eddy covariance flux measurements using pulsed quantum cascade tunable infrared laser differential absorb

Better quantification of atmosphere-ecosystem exchange of the isotopologues of CO2 could substantially improve our ability to probe underlying physiological and ecological mechanisms controlling ecosystem carbon exchange, but the ability to make long-term continuous measurements of the isotopic composition of exchange fluxes has been limited by measurement difficulties. Quantum cascade (QC) las...

متن کامل

Recent Advances in Trace Gas Detection Using Quantum and Interband Cascade Lasers

There is an increasing need in many chemical sensing applications ranging from environmental science to industrial process control as well as medical diagnostics for fast, sensitive, and selective trace gas detection based on laser spectroscopy. The recent availability of novel pulsed and continuous wave (cw) quantum and interband cascade distributed feedback (QC and IC DFB) lasers as mid-infra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 24 23  شماره 

صفحات  -

تاریخ انتشار 1999