The radiation reduction methods in imaging need more attention.

نویسنده

  • Juhani Knuuti
چکیده

The use of imaging in cardiology has been rapidly growing during recent years. New techniques such as computed tomography have been introduced, but also the use of more established techniques such as nuclear myocardial perfusion imaging (MPI) and cardiac magnetic resonance imaging has been growing globally. The potential risks of imaging have recently been actively discussed. These risks include the imaging procedures themself, the stressors used, the contrast agents, and the ionizing radiation. Although the use of more non-invasive methods is probably increasing patient safety, concerns due to other risks have been raised. One of the risk components is that related to ionizing radiation. In many situations such as in the elderly or in patients with low life expectancy, the risk of radiation is exceedingly small and radiation is not the main issue when an imaging test is selected. Although the risk of radiation caused by imaging may be considered similar to many other risks of imaging and normal life activities, and much less than those of the disease itself, it cannot be disregarded. According to the ALARA principle (as low as reasonably achievable), all meaningful opportunities to reduce the risk due to radiation should be taken. Consequently, numerous recommendations and methods to minimize the radiation dose for patients have been published. In the present issue of the journal, an expert team jointly with the International Atomic Energy Agency (IAEA) have published a study about how radiation reduction strategies are used globally in MPI. The team conducted a survey in centres performing MPI in all continents. Nuclear cardiology laboratories and practitioners were contacted and information about their practice over a 1-week period in Spring 2013 were collected. The survey provided interesting data. While the global mean radiation dose was in the range that has been published many times previously (10.0+ 4.5 mSv), the variability of doses between the centres was huge (range 2.2–24.4 mSv). There were also clear differences in radiationdosesbetweengeographical regions. Europehad the lowest doses, while Latin America, North America, and Asia had the highest doses. The doses from African centres were also in the lowest range but the data were from a small number of sites, which, however, may well reflect the current situation in that continent. Interestingly, but maybe not surprisingly, the radiation doses were inversely related to the adherence to best practices in reducing radiation (defined prior to survey). The best practices were evaluated on the basis of how the centres utilized the simple techniques that are effective in reducing radiation dose without compromising the diagnostic value of the test. If all eight methods were in use, the maximum score of 8 was given. The global median score was a decent 5, but the variability was large. An important finding was that the World Bank income level and laboratory volume were not associated with the score. This kind of survey is naturally not without limitations. One of the main limitations is that it is not known whether laboratories are representive of all nuclear cardiology laboratories worldwide and it was not possible to estimate what percentage of all existing centres participated. Respondents may represent a subset of laboratories with a better best practice use. Also the survey focused only on radiation dose optimization; the image quality was not assessed and the appropriateness of the examinations was not studied. Despite these limitations, the message of the survey became clear: the radiation reduction methods are far from fully exploited. Although Europe was among the highest in adherence to best practices and lowest in radiation doses, one cannot be satisfied with the situation. The European sites complied poorly with some very simple methods to reduce radiation doses. The use of stress-only imaging was reported in only 46% sites and weight-based dosing for technetium in 47% of sites. Europe’s advantage came mainly from the fact that other regions more often used thallium and unnecessarily high doses of tracer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

Image Optimization and reduction of radiation dose in CT of the paranasal sinuses

Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...

متن کامل

حفاظت پرتویی بیماران در سی تی آنژیوگرافی قلب

Introduction: Cardiac CT (Computed Tomography) angiography applies as a pre-exam method for evaluating the patients with medical problems in their cardiac arteries. Due to the high delivered dose in this imaging method, dose reduction techniques and imaging strategies that serve the images quality with minimum patient dose are the subjects for investigation and research studies. This study will...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 36 26  شماره 

صفحات  -

تاریخ انتشار 2015