Imaging atrial septal defects by real-time three-dimensional transesophageal echocardiography: step-by-step approach.
نویسندگان
چکیده
BACKGROUND There are currently no standardized three-dimensional (3D) transesophageal echocardiographic (TEE) views of the interatrial septum and atrial septal defects (ASDs). Without a standardized approach, it is difficult to ascertain the important anatomic relationships (such as the location of the aortic rim of an ASD), to perform relevant measurements (such as the size of an ASD or the size of its rims), or to guide the deployment of catheters and devices during atrial septal closure. METHODS Using a 3D TEE matrix-array transducer, 706 TEE studies were performed over a 14-month period. The purpose of the study was to develop a standardized protocol for anatomically correct orientation of 3D TEE images of the interatrial septum and ASDs. RESULTS Among 706 TEE studies, there were 23 patients with ASDs, representing 3.3% of the study population. Eighteen patients had secundum ASDs, two had primum ASDs, and three had sinus venosus ASDs of the superior vena cava type. A protocol for properly orienting 3D TEE images of the interatrial septum and ASDs was developed. When the images are acquired at an angle of 0°, the septum is properly oriented by the tilt-up-then-left maneuver. The initial 3D TEE image in first tilted up to reveal the right atrial side of the septum. Then the image is tilted 180° around its vertical axis to reveal the left atrial side of the septum; the aortic rim is on the left, the superior vena cava on the top, and the right-sided pulmonary vein ostia on the right side of the screen. For acquisitions at a higher angle, the rotate-left-in-z-axis maneuver is used. The image is first tilted up to reveal the right atrial side of the septum, as in the tilt-up-then-left maneuver. The image is then rotated counterclockwise in the z axis until the superior vena cave is at 12 o'clock. Finally, the image is tilted 180° around its vertical axis to reveal the left atrial side of the septum. CONCLUSIONS The use of standardized tilt-up-then-left and rotate-left-in-z-axis maneuvers enhances the diagnosis of ASDs, ascertains the important anatomic relationships of ASDs to surrounding structures, and facilitates communication between echocardiographers obtaining 3D TEE images and interventional cardiologists or cardiac surgeons performing ASD closures.
منابع مشابه
Imaging Atrial Septal Defects by Real-Time 3D Transesophageal Echocardiography: Step-by-Step Approach
Background: There are currently no standardized three-dimensional (3D) transesophageal echocardiographic (TEE) views of the interatrial septum and atrial septal defects (ASDs). Without a standardized approach, it is difficult to ascertain the important anatomic relationships (such as the location of the aortic rim of an ASD), to perform relevant measurements (such as the size of an ASD or the s...
متن کاملThree-dimensional transesophageal echocardiography of the atrial septal defects
Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophagea...
متن کاملPostoperative dissecting ventricular haematoma: a conservative strategy with a cardiac magnetic resonance imaging follow-up.
assessment of percutaneous patent foramen ovale and atrial septal defect closure complications. Circ Cardiovasc Imaging 2009;2:141–9. 22. Faletra FF, Nucifora G, Ho SY. Imaging the atrial septum using real-time threedimensional transesophageal echocardiography: technical tips, normal anatomy, and its role in transseptal puncture. J Am Soc Echocardiogr 2011;24:593–9. 23. van den Bosch AE, Ten Ha...
متن کاملHorseshoe-like Shaped Atrial Septal Defects Confirmed on Three-Dimensional Transesophageal Echocardiography
A 51-year-old female with exertional dyspnea was admitted. Transthoracic echocardiography (TTE) revealed 2 defects at interatrial septum with left to right shunt (Fig. 1A). En face display of the interatrial septum by three-dimensional (3D) TTE demonstrated two ovoid atrial septal defects (ASDs). Two ovoid defects and interatrial septum formed like horseshoe (Fig. 1B). Transesophageal echocardi...
متن کاملTranscatheter closure of perimembranous ventricular septal defects with Amplatzer occluder assessed by real-time three-dimensional echocardiography.
We report our initial experience in two patients using real-time three-dimensional echocardiography to assess perimembranous ventricular septal defect and device morphology and their relation with contiguous cardiac structure. Defect size and rims as well as device position and profile were displayed from the three-dimensional "en face" views. We think that real-time three-dimensional echocardi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 23 11 شماره
صفحات -
تاریخ انتشار 2010