Emc 2002 International Wrocław Symposium and Exhibition on Electromagnetic Compatibility Validation of Semi-anechoic Chambers with Tuned Halfwave-dipoles Working over a Wide Frequency Band
نویسندگان
چکیده
In this paper the latest techniques for validation of anechoic chambers are described. The Short Dipole Site Validation Method (SDSV) is based on the use of the CISPR 16 dipole in an expanded, non-resonant frequency range. The SDSV idea is great as it combines advantages of the Site Reference method (direct comparison of two site attenuations, no antenna factors involved, quasi-swept frequency scan, fast, volumetric) with advantages of the tuned half-wave dipole method (numerically calculable, very accurate). We have compared site validations done according to the Site Reference Method to SDSV results. Thereby we encountered several disadvantages of this new SDSV procedure. Due to the high antenna factors below the resonance frequency a good dynamic range of the test receiver is required. Another problem is the amount of time needed for the measurements. A set of at least three dipole pairs is required to cover the frequency range from 30 MHz to 1 GHz instead of two broadband antennas. The antenna pattern of dipole and broadband antenna are different this leads to different results in the site validation. For chamber validation the performance of the chamber itself should be checked. Therefore the antenna system for the validation procedure must be calibrated under exactly the same setup conditions (including antenna mast, tripod and antenna cables) as used for site validation. In the numerical simulation of the SDSV reference these influences can not be considered. Finally there is no reason to prefer the SDSV method to the site reference method.
منابع مشابه
Site-Reference Method for EMC Test Site Validation
Electromagnetic compatibility (EMC) compliance testing for the CE-certification of electronic apparatus involves the measurement of radiated-emissions in the frequency range of 30 MHz to 1 GHz. To achieve equivalent test results from different testing laboratories, test sites must be of validated, standard performance. This paper suggests two substantial improvements to the standard site valida...
متن کاملA Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System
Power line communication (PLC) system is spreading as a new communication system without providing new infrastructure for network communication. However, It is needed to investigate the EMI problem caused by PLC, and it is often tested in an anechoic chamber and an open area test site (OATS). The semi anechoic chamber lined ferrite tiles used for EMC testing is not generally designed in the fre...
متن کاملCalibration of Antenna for EMI Measurements in Compact Semi-anechoic Rooms
The accurate knowledge of the antenna factor is a fundamental requirement for reliable electromagnetic compatibility (EMC) measurements in emissions, immunity and human exposure tests. According to international standards, this would imply calibrating antennas in close-to-ideal test sites (calibration test sites), characterized by very large sizes of the ground plane and of the empty space volu...
متن کاملهینهسازی مسیر هادیهای انتقال در محفظه فلزی تجهیزات الکتریکی مبتنی بر سازگاری الکترومغناطیسی با استفاده از روش تصمیمگیری چند معیاره مطالعه موردی: سیستم تزریق جریان 25 کیلو آمپر
The higher frequency transient signals generated as a result of a power system fault or disturbance provide the basis for an alternative approach to power system containing connectors and cables result in unsuitable operation of the system. However one major challenge is the need to ensure that the transients to be neutralized by electromagnetic compatibility (EMC) issues and cabling routes. T...
متن کاملAn Interpolation Method to Calibrate Elec- Tromagnetic Probes in Semi-anechoic Cham- Bers
Based upon the standard IEEE 1309, a new calibration method for electromagnetic (EM) probes is proposed. The aforementioned method compares the electric field strength measured with the EM probe subject to calibration with the E-field intensity calculated through a linear interpolation of the corrected measurement using a reference EM probe. The corrected measurement results are computed by mea...